- Research
- Open access
- Published:
Univariate versus multivariate spectrophotometric data analysis of triamterene and xipamide; a quantitative and qualitative greenly profiled comparative study
BMC Chemistry volume 17, Article number: 47 (2023)
Abstract
Triamterene (TRI) and xipamide (XIP) mixture is used as a binary medication of antihypertension which is considered as a major cause of premature death worldwide. The purpose of this research is the quantitative and qualitative analysis of this binary mixture by green univariate and multivariate spectrophotometric methods. Univariate methods were zero order absorption spectra method (D0) and Fourier self-deconvolution (FSD), as TRI was directly determined by D0 at 367.0 nm in the range (2.00–10.00 µg/mL), where XIP show no interference. While XIP was determined by FSD at 261.0 nm in the range (2.00–8.00 µg/mL), where TRI show zero crossing. Multivariate methods were Partial Least Squares, Principal Component Regression, Artificial Neural Networks, and Multivariate Curve Resolution-Alternating Least Squares. A training set of 25 mixtures with different quantities of the tested components was used to construct and evaluate them, 3 latent variables were displayed using an experimental design. A set of 18 synthetic mixtures with concentrations ranging from (3.00–7.00 µg/mL) for TRI and (2.00–6.00 µg/mL) for XIP, were used to construct the calibration models. A collection of seven synthetic mixtures with various quantities was applied to build the validation models. All the proposed approaches quantitative analyses were evaluated using recoveries as a percentage, root mean square error of prediction, and standard error of prediction. Strong multivariate statistical tools were presented by these models, and they were used to analyze the combined dosage form available on the Egyptian market. The proposed techniques were evaluated in accordance with ICH recommendations, where they are capable of overcoming challenges including spectral overlaps and collinearity. When the suggested approaches and the published one were statistically compared, there was no discernible difference between them. The green analytical method index and eco-scale tools were applied for assessment of the established models greenness. The suggested techniques can be used in product testing laboratories for standard pharmaceutical analysis of the substances being studied.
Introduction
Applying green reagents in the establishment of ecological analytical techniques has significantly increased in recent years. Green analytical chemistry (GAC) is the practice of minimizing or avoiding the use of potentially harmful chemicals in analytical processes while reducing energy use, waste creation, and other environmental impacts [1, 2]. For quality control professionals, using environmentally friendly techniques for routine drug assessment is of the most important aims and this is what GAC aims to provide. The National Environmental Approaches Index (NEMI), Assessment of Green Profile (AGP), Green Analytical Procedure Index (GAPI), and eco-scale were a few tools for gauging how environmentally friendly a proposed analytical methodology was. These tools were largely based on the 12 guidelines provided by Gauszka et al [3].
Globally, hypertension affects an estimated 26% of the global populace and the prevalence is expected to rise to 29% by 2025 [4]. Heart attacks and strokes are the most common killers worldwide. They are mostly caused by high blood pressure, which was the most important modifiable risk factor globally in 2013 [5]. There are three medication classes that most commonly used to treat hypertension [6]. The chemical name of triamterene (TRI) is 6-phenylpteridine-2, 4, 7-triamine (Fig. 1) [7]. It is a potassium-sparing diuretic preventing hypokalemia in the body and is also used for the treatment of edema [8]. The chemical name of xipamide (XIP) is 4-chloro-N-(2, 6-dimethyl phenyl)-2-hydroxy-5-sulfamoylbenzamide) (Fig. 1) [7]. It is a diuretic medication used to treat hypertension and shares some characteristics with thiazide diuretics, including its effects on hypokalemia [8]. The combination of TRI and XIP is available in the Egyptian market under the trade name Epitens®tablets (each tablet contains 30.0 mg and 10.0 mg for each TRI and XIP, respectively) for treating hypertension.
Reviewing the literature illustrated various spectrophotometric assessments for this mixture in its pharmaceutical formulation for the simultaneous estimation of the combination of TRI and XIP [8,9,10]. Additionally, various chromatographic techniques for the quantitative evaluation of this mixture were reported [10,11,12]. A review of the literature also showed that the reported methods did not assess the degree of greenness.
This project aimed to develop first green and accurate univariate and multivariate spectrophotometric approaches for binary mixture analysis of TRI and XIP using UV spectral data in their pure and pharmaceutical formulations and compare between them. Univariate methods such as Zero order (D0) and Fourier self-deconvolution (FSD) method, while multivariate approaches, such as, partial least squares (PLS) regression and principal component regression (PCR), artificial neural networks (ANN), and Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) The current work environmental friendliness helped to reduce any harmful ecological consequences of potentially hazardous materials or study methods. Here, the greenness of the employed chemicals and processes was evaluated utilizing GAPI and penalty points scoring systems. A reliable method, from collection of samples through ultimate analysis, GAPI may provide a comprehensive environmental evaluation of the whole analysis process [13]. Depending on penalty points, the eco-scaling of the developed methodologies was computed and deducted from 100 [14]. ICH techniques were employed to evaluate the established models [15]. The published HPLC approach and the existing methodologies showed no appreciable differences in the statistical analysis.
Experimental
Instruments and software
The UV- Visible spectrophotometer JASCO dual beam (Tokyo, Japan) model V-630 was utilized with the included programmer spectra II manager. The spectral slit had a width of 2 nm, and the scanning rate was 1000 nm/min. All chemometric techniques were applied using MATLAB®8.3.0.532 (R2014a), PLS Toolbox (version 2.1), MCR-ALS Toolbox, and Neural Network Toolbox (Math Works, United States).
Materials
Egyptian International Pharmaceutical Industries Co. (EIPICO; Cairo, Egypt) gratefully provided pure samples of TRI and XIP. According to the official method, their purity was found to be 100.13% ±1.03 and 99.25% ± 0.946 for TRI and XIP, respectively [7]. Pharmaceutical dosage form- Epitens®tablets were produced by EIPICO. Each tablet contains 30.0 mg and 10.0 mg for each TRI and XIP, respectively, as main components.
Preparation of standard solutions
Different stock solutions of TRI and XIP (1.00 mg/mL) were created by dissolving 100.0 mg of each drug in 100 mL of methanol. The volume was filled with methanol to make the working solutions for TRI and XIP (100.00 µg/mL) after 10 mL of each drug solution was diluted from its stock standard solutions into two separate 100 mL volumetric flasks. Methanol of analytical grade was purchased from El-Nasr Pharmaceutical Chemicals Co. Cairo, Egypt.
Procedures
Creation of calibration curve
Univariate methods
Two isolated sets of 10 ml volumetric flasks were used to accurately transfer multiple aliquots of TRI and XIP from each stock standard solution in order to create linearity ranges (2.00–10.00 µg/mL) and (2.00–8.00 µg/mL) for TRI and XIP, respectively.
-
Zero order absorption spectra method
The TRI and XIP absorption spectra were acquired spanning the wavelength range of 200.0 to 400.0 nm. The linear regression was calculated after the calibration curve was drawn between both the absorbance at 367.0 nm and the appropriate TRI concentrations.
-
Fourier self-deconvolution spectrophotometric method
Utilizing the FSD function, each drug spectra was analyzed and deconvoluted separately. The amplitude of the substance deconvoluted signal at 261.0 nm was plotted to produce the calibration curve for XIP in binary mixture. The pharmaceutical formulation form and laboratory-prepared mixtures were both generally calculated using the linear relationship that was generated.
Multivariate methods
Both calibration and validation datasets were created utilizing the five-level, two-factor experimental design and five concentration levels labelled from + 2 to -2 for each of the two medications under evaluation. Concentration ranges of TRI and XIP which used for calibration and validation sets were (3.00–7.00 µg/mL) and (2.00–6.00 µg/mL) respectively. 25 samples comprising mixtures of TRI and XIP in varied ratios were created by transferring various concentrations of TRI and XIP from their corresponding working solutions to a series of 10-mL volumetric flasks. To assess the predictive power of each built calibration model, seven samples were randomly chosen for the cross validation set and the rest of them were utilized to build the regression model. With 0.1 nm interval, the absorption spectra of the calibration and validation sets were scanned at wavelength range of 220.0–240.0 nm. The results were then imported into MATLAB®to be used in multivariate calibration models and additional data processing, including PLS, PCR, ANN, and MCR-ALS, were built. Each technique parameter was examined and improved. The two medications were then determined jointly using the cross validation set and the previously defined criteria for each model.
-
Principal component regression and partial least squares
With the aid of mean-centered data and leave-one-out cross validation, the number of latent variables (LVs) and principal component (PC) in the PLS and PCR, respectively calibration models were altered. The ideal number of LVs and PC to achieve the lowest root mean square calibration error (RMSEC) was three.
-
Artificial neural networks
A feed-forward model was trained to enhance the ANN calibration method. There were 201 and 2 neurons in the input and output layers, respectively. It was also attempted to optimize the hidden layer’s number of neurons. Purelin-purelin transfer function, which is often employed for linear processes, was utilized to choose 8 neurons from the hidden layer. Furthermore, 100 epochs were chosen as the optimal number.
-
Multivariate curve resolution-alternating least squares
The most crucial optimization factor in MCR-ALS calibration was the imposed constraints; non-negativity constraints, which were obtained using the fast non-negativity constrained least squares algorithm (fnnl), were implemented to both concentration and spectral profiles in order to obtain optimum features with the fewest iterations.
Laboratory prepared mixtures analysis
The ratios of five different laboratory TRI and XIP combinations were created in two various sets, and the measurements were taken between 200.0 and 400.0 nm for each set. To quantify the concentration of each medication individually, the aforementioned techniques were applied. The steps outlined below (building calibration curves for univariate methods) were adhered to, and the associated linear regression was employed to estimate each drug’s concentration.
Analysis of a drug formulation
A clean mortar and pestle was utilized to weigh, properly crush, and mix 20 Epitens®pills. The exact amount of smashed powder needed to make a solution with 1000.0 µg/mL was put into a 25 mL volumetric flask, and then 15 mL of methanol was added. The created solution was cooled, diluted to volume with methanol, and filtered after being sonicated for 30 min. To achieve the right dilutions and final concentrations of 6.00 µg/mL for TRI and 2.00 µg/mL for XIP, respectively, the correct dilutions were made using the same solvent. Following the aforementioned methods, each drug’s concentration was calculated using the associated regression equations. In their tablet, the developed methodologies were successful in recognizing TRI and XIP.
Results and discussion
Comparing spectrophotometric approaches to others that require complex equipment or chemical pretreatment, such as chromatographic techniques, spectrophotometric methods have the benefits of being quick, easy, and inexpensive [16]. The current study offers a simple, environmentally friendly UV spectrophotometric techniques for assessing TRI and XIP simultaneously in pharmaceutical and bulk forms.
A quantitative measurement of TRI was made at zero-order spectra at 367.0 nm (Fig. 2), and XIP was resolved and quantified by FSD method at 261.0 nm. The FSD approach tends to reduce excessively overlapping spectra, enhancing the resolution of overlapping spectra by eliminating the broadening impact caused by the spectrophotometer convolution [17].
Multivariate approaches can be used to quickly predict analytes concentrations by evaluating spectra from unknown chemicals using a multivariate model [18]. Numerous spectrophotometric techniques have been previously published for evaluating TRI and XIP in dosage forms, but there is no reported chemometric methods till nowadays. Here, the proposed techniques’ “greenness” was evaluated using a brand-new and powerful scoring method called the “greenness assessment tool.“
Univariate method
Zero order absorption spectra method
It is the simplest way for evaluating a mixture since one component can be detected directly and the other medicines do not interact with it [19, 20]. Spectra in (Fig. 2) showed that TRI was extended than XIP so it can be measured in zero absorption spectra at 367.0 nm. While XIP showed no interference, TRI was assessed over the linearity range (2.00–10.00 µg/mL) and detected at 367.0 nm.
Fourier self-deconvolution spectrophotometric method
FSD is recognized as an efficient mathematical computing technique that is applied in a number of signal processing applications. The physical convolution brought on by instrumental distortions to spectrum signals was eliminated by the currently employed technique. What gives the current methodology its resolving capacity is the evolution of major spectral zones with zero-crossing or no contribution points between the spectra of mixed components [17]. Reversing the physical convoluting, distorting impacts from the spectrophotometer performed to the recorded spectrum is the underlying idea behind FSD [21]. The resolution and determination of TRI and XIP in their binary mixture were described by the current FSD method. Since TRI overextended than XIP, as TRI zero-order spectrum was previously calculated. The spectra manager software’s full width at half maximum value (FWHM) function was used to automatically deconvolute the zero-order spectra of XIP and TRI with FWHM value of 65. XIP calibration curve was plotted at 261.00 nm over linearity range (2.00–8.00 µg/mL) was the respective zero-crossing point for TRI as shown in (Fig. 3). By examining the laboratory-prepared mixtures with various TRI and XIP ratios, the specificity of the suggested methods was evaluated. The obtained results were satisfactory were as shown in (Table 1).
Multivariate methods
The main advantage of multivariate analysis is that it considers more than one factor in data analysis. It looks at the various independent variables that influence the dependent variable, not like univariate analysis which depend on one variable [18, 22]. Using multivariate data processing, the substantially overlapping drug spectra were separated. The investigation of TRI and XIP used four multivariate techniques. For the multivariate calibration to produce the best predictions, a detailed experimental design of the calibration set’s composition is required. To construct the samples, a multilevel multifactor design was utilized, with 18 samples serving as a training set and the remaining 7 samples serving as a validation set (Table 2). The range of spectra between 220.0 and 240.0 nm, each scanned at 0.1 nm, produced the best results. 201 experimental points were utilized to calibrate and evaluate the established models. To predict unknown samples, calibration models were proposed, tested, and used.
Principal component regression and partial least squares
The most frequently employed inverse least squares for building multivariate calibration models are PCR and PLS [23,22,25]. In the statistical study of spectra, PLS and PCR algorithms are frequently employed to extract detailed data from more general data [26, 27]. The PLS and PCR algorithms simultaneously consider the data about replies and levels [28, 29]. The leave one out cross-validation method was used in this research to determine the appropriate number of components by excluding one sample at a time. The optimal number of LVs is the one that results in the fewest significant predictions errors [25, 30]. In this case, three latent variables were shown to be the optimum number. (Figs. 4 and 5).
Artificial neural networks
ANN is a method for imitating intelligence that finds links between inputs and outputs by using a large number of simple, densely linked nodes or artificial neurons. Three layers input, hidden, and transfer functions make up an ANN typically [31, 32]. The feed-forward model that was trained is the ANN type that was employed in this study. Two neurons were utilized in the output layer, equivalent to the number of components intended to be evaluated in each sample, and 201 neurons were utilized as the input layer, representing how many spectral data points were applied. Trial-and-error should be employed to alter the hidden layer’s number of neurons. With 100 epochs and a purelin-purelin transfer function, 8 hidden neurons were the ideal number. The output plot of an appropriately trained ANN for mean squared error (MSE) versus epochs is shown in (Fig. 6). The MSE of training gradually dropped after epoch = 0. The trial and validating curves were similar and showed no abrupt changes, supporting the idea that there was no overfitting. In (Fig. 7), prediction diagrams for the training, test, and validation series of the chosen layers and neurons are also shown. For validation, test and training series, the high effectiveness of this model in prediction is indicated by a correlation value (R) that is near to 1 [33].
Multivariate curve resolution-alternating least squares
Factor analysis is utilized to develop the multi-wavelength extension of Beer’s-Lambert law, and MCR implies a bilinear model [31]. The spectral and concentration -profile matrices of each drug in the samples are separated out from the measured spectra data matrix in MCR, and error is then determined [32, 34]. The ALS approach was optimized for repeated concentration predications from spectral profiles and vice versa. Data matrix decomposition does not have a unique solution, hence by placing limitations like uni-modality, closure, equality, or non-negativity, it is possible to decrease the number of alternative solutions.
“simple-to-use interactive self-modeling analysis” technique was used to estimate spectral-profile matrix to begin the optimization of ALS [35]. Additionally, the unconstrained least-squares solution for the concentration profile was computed using the spectral-profile matrix.
In the present work, both concentration and spectral profiles were subjected to non-negativity constraints. Both concentration and spectra have to equal 2 to satisfy the non-negativity constraints. When a specific convergence threshold was reached, the ALS optimization process came to an end (30%). The convergence is frequently stopped (typically set at 0.1%) when the variation between the root mean square of “E” the residuals matrix, between multiple iterations, is lower than a threshold level [33]. Iterations processed till an ideal result is found which satisfies both the set convergence criteria and the hypothesized limitations. At two iterations, the convergence was interrupted. The computed percentages of variance (R2) and lack of fit (% lof) were 99.9829 and 1.3084, respectively, and they were sufficient to support the effectiveness of the provided MCR-ALS model. These model could be used to estimate the spectral profile of medications. The calculated spectra are seen to resemble the original ones (Fig. 8). The values of the recoveries, mean recoveries, and RSD % are shown in (Table 3).
Table 4 provides the regression and validation parameters for the proposed spectrophotometric methods for determining pure TRI and XIP samples, the validation process followed ICH criteria [15]. Sensitivity is the change in the response of a measuring instrument divided by corresponding change in the stimulus or simply the gradient of the calibration function; the lower the LOD and LOQ, the higher the sensitivity [15]. Values of LOD and LOQ for developed methods were mentioned in (Table 4) while values of LOD for literature method were 0.58 and 0.67 for TRI and XIP, respectively and LOQ values were 1.78 and 2.03 for TRI and XIP, respectively. Root mean square error of prediction (RMSEP) and RMSEC and for each component were also computed by the proposed multivariate models.
Greenness assessment
In order to assess whether different analytical techniques adhered to the green chemistry theory, it was crucial to evaluate their environmental impact. Various techniques can be employed to evaluate the greenness of everything [36]. Ecological impact of analytical techniques was assessed using four primary factors: high energy consumption, high waste production, excessive chemical use and its dangers, and the use of large amounts of chemicals [37, 38]. The greenness of the suggested technique was assessed in addition to its cost-effectiveness utilizing two analytical tools, and they were as follows:
Green analytical procedure index
Wasylka [3] proposed a noval metric for evaluating greenness. It is a tool that provides a wealth of knowledge on fifteen areas of analytical techniques, each of which is symbolized by five pentagrams. Red indicates a significant environmental risk, yellow indicates to lesser ecological tolerance while green indicates higher ecological tolerance according to the GAPI color scheme [3, 39]. Analytical procedures examined by the GAPI tool were given a green evaluation profile as shown in (Fig. 9). It shows that the established methods were a simple, environmentally friendly methods that could be used for both characterization and measurement without the requirement for extraction strategies. Additionally, it offered uncomplicated processes that generated the least quantity of waste and dangerous substances.
Analytical eco-scale
It is feasible to compare and choose the greenest option by using an analytical technique called the eco-scale [40, 41]. It uses a basis of 100 penalty points. Penalty points are determined for each analytical technique parameter and reduced from 100. The higher the score, the more ecofriendly and economically efficient the analytical technique [14]. (Table 5) demonstrated that the proposed methodologies provide 11 penalty points, which indicates excellent green analysis with fewer waste and potentially harmful reagents.
Comparative statistical study
For the accurate estimation of TRI and XIP in Epitens® tablets D0, FSD, PLS, PCR, ANN, and MCR-ALS techniques were applied. Statistics were used to evaluate the result of the established regression techniques to those produced using the reported technique [11]. The recommended methodologies and the reference method showed great agreement, as shown by the F-ratio test and t-test. The differences between the two experiments’ results were found to be insignificant, and all findings were collected in (Table 6).
When the described techniques were applied to the preparation of pharmaceuticals, the recovery % data were compared statistically using one way-ANOVA; no substantial differences were found (Table 7). These results support the applicability of the developed models for the precise estimation of TRI and XIP in their pharmaceutical preparation.
Column charts show the RMSEP and RMSEC calculated using the suggested validation and calibration models for each ingredient (Fig. 10). The PCR model has the lowest RMSEP and RMSEC, per the findings. To demonstrating the method’s precision and reliability, RMSEP is a diagnostic tool for evaluating prediction mistakes. RMSEP measures the range of concentration mistakes and acts as a standard deviation [42]. The optimal model for determining a numerical ingredient was found to be the PCR model.
Conclusion
The suggested spectrophotometric techniques can be utilized for the concurrent evaluation of the studied binary mixture in dosage form using straightforward procedures and minimal manipulation. The two compound in their standard and medicinal forms could be analyzed using the suggested green methods quickly, easily, and with excellent sensitivity and reliability. The current methodologies greenness was taken into consideration during the early stages of their development, and it was subsequently evaluated utilizing the GAPI index and the penalty point scoring system. statistically, the proposed and reported methods did not significantly differ, demonstrating the sensitivity, accuracy, and precision of both. The six recommended strategies, however, are less troublesome and more appropriate for determining the drug mixture under study.
Availability of data and materials
Spectrophotometric data obtained from spectrophotometer software. Datasets generated and/or analyzed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- TRI:
-
Triamterene
- XIP:
-
Xipamide
- D0 :
-
Zero order absorption spectra method
- FSD:
-
Fourier self-deconvolution
- GAC:
-
Green analytical chemistry
- NEMI:
-
National environmental approaches index
- AGP:
-
Assessment of green profile
- GAPI:
-
Green analytical procedure index
- PLS:
-
Partial least squares regression
- PCR:
-
Principal component regression
- ANN:
-
Artificial neural network
- MCR-ALS:
-
Multivariate curve resolution-alternating least squares
- HPLC:
-
High performance liquid chromatography
- LVs:
-
Latent variables
- RMSEC:
-
Root mean square calibration error
- FWHM:
-
Full width at half maximum
- MSE:
-
Mean squared error
- RMSEP:
-
Root mean square error of prediction
- μg:
-
Microgram
- mL:
-
Milliliter
- nm:
-
Nanometer
- ICH guidelines:
-
International council on harmonization
- SD:
-
Standard deviation
- RSD:
-
Relative standard deviation
References
Lamie NT, Mohamed HM. Application and validation of an eco-friendly TLC- densitometric method for simultaneous determination of co-formulated antihypertensive, RSC Adv. 2015; 5:59048–59055. https://doi.org/10.1039/c5ra08125d.
Eissa MS, Abd El-Hadi HR, Zaazaa HE, Eltanany BM. Smart TLC–densitometric methods for determination of ophthalmic ternary mixture containing chloramphenicol in the presence of its synthetic precursor: comparative eco-scaling for greenness assessment. J Planar Chromatogr Mod TLC. 2020;33:501–9. https://doi.org/10.1007/s00764-020-00055-8.
Wasylka J. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index, Talanta. 2018;181:204–209. https://doi.org/10.1016/j.talanta.2018.01.013.
Kearney PM, Whelton M, Reynolds K, Muntner P. Global burden of hypertension: analysis of worldwide data, Lancet. 2005; 365:217–223. https://doi.org/10.1016/s0140-6736(05)17741-1.
Naghavi M, Wang H, Lozano R, Davis A, Liang E. Global, regional, and national age-sex specific all-cause and cause-specific mortality for 240 causes of death, 1990–2013: a systematic analysis for the global burden of disease study 2013, Lancet. 2015;385:117–171. https://doi.org/10.1016/S0140-6736(14)61682-2.
Becker FG, Cleary M, Team RM, Holtermann H. Clinical guidlines for the mangment of hypertension, 2015.
British Pharmacopoeia, Stationary Office, Appendix 1D, Buckingham Palace Road, London, UK, 2016.
Fares NV, El Fiky HA, Badawey AM, Abd MF, Ghany E. Simultaneous determination of xipamide and triamterene by first derivative, ratio difference, and derivative ratio spectrophotometric methods. Arch Pharm Sci Ain Shams Univ. 2021;5:52–62. https://doi.org/10.21608/aps.2021.58496.1053.
Abdel-monem AH. Simultaneous spectrophotometric estimation of triamterene and xipamide in pure form and pharmaceutical formulation by iso-absorptive point dependent methods. Anal Chem Lett. 2018. https://doi.org/10.1080/22297928.2017.1395293.
Wagieh NE, Abbas SS, Abdelkawy M, Abdelrahman M. Spectrophotometric and spectrodensitometric determination of triamterene and xipamide in pure form and in pharmaceutical formulation. Drug Test Anal Publ. 2010. https://doi.org/10.1002/dta.92.
EL-Kimary EI. Stability-indicating HPLC – DAD method development, validation, and stress degradation studies for triamterene and xipamide in their combined tablet dosage form, Acta Chromatogr. 2016; 28: 79–98.
Ayad MM, Hosny MM,Ehab A, El-abassy OM, Belal FF. An eco-friendly micellar HPLC method for the simultaneous determination of triamterene and xipamide in active pharmaceutical ingredients and marketed tablet dosage form, Acta Chromatogr. 2021;33:51–65. https://doi.org/10.1556/1326.2020.00746.
Wasylka J, Rutkowska M, Owczarek K, Tobiszewski M, Namieśnik J. Extraction with environmentally friendly solvents. Trends Anal Chem. 2017;91:12–25. https://doi.org/10.1016/j.trac.2017.03.006.
Atty SA, Abd El Hadi HR, Eltanany BM, Zaazaa HE, Eissa MS. Analytical eco – scale for evaluating the uniqueness of voltammetric method used for determination of antiemetic binary mixture containing doxylamine succinate in presence of its toxic metabolite, Electrocatalysis. 2022;13;731–746. https://doi.org/10.1007/s12678-022-00751-5.
ICH Guideline, Validation of analytical methods: definitions and terminology, ICH Top. Q2A. London. 1994.
Kelani KM, Hegazy MA, Hassan AM, Tantawy MA. Univariate versus multivariate spectrophotometric methods for the simultaneous determination of omarigliptin and two of its degradation products. Spectrochim Acta - Part A Mol Biomol Spectrosc. 2022;271:120880. https://doi.org/10.1016/j.saa.2022.120880.
Elsonbaty A, Attala K. An eco-friendly modified methodology for the resolution of binary pharmaceutical mixtures based on self-deconvolution of the UV spectrophotometric spectra in the fourier domain: application of fourier self-deconvolution in UV spectroscopy, Spectrochim. Acta - Part A Mol Biomol Spectrosc. 2022;264:120262. https://doi.org/10.1016/j.saa.2021.120262.
Hegazy MA, Yehia AM, Moustafa AA. Bivariate versus multivariate smart spectrophotometric calibration methods for the simultaneous determination of a quaternary mixture of mosapride, pantoprazole and their degradation products, Pharmazie. 2013;68:317–326. https://doi.org/10.1691/ph.2013.2196.
Eltanany BM, Abd El-Hadi HR, Zaazaa HE, Eissa MS. In vitro analytical dissolution profiling of antiemetic delayed release tablets in two different dissolution media: validated spectrophotometric methods versus reported HPLC, Spectrochim. Acta - Part A Mol. Biomol Spectrosc. 2021;246:1–8. https://doi.org/10.1016/j.saa.2020.119013.
Eltanany BM, Abd El-Hadi HR, Zaazaa HE, Eissa MS. Spectrophotometric methods for the determination of chloramphenicol dexamethasone sodium phosphate and tetrahydrozoline HCl in their pure and ophthalmic dosage forms. J Appl Spectrosc. 2021;88:1081–87. https://doi.org/10.1007/s10812-021-01283-4.
Attala K, Elsonbaty A. Advanced eco-friendly UV spectrophotometric approach for resolving overlapped spectral signals of antihypertensive agents in their binary and tertiary pharmaceutical dosage form. Spectrochim Acta - Part A Mol Biomol Spectrosc. 2021;258:119855. https://doi.org/10.1016/j.saa.2021.119855.
Hegazy MH, Eissa MS , Abd El-Sattar OI , Abd El-Kawy, MM, Determination of a novel ACE inhibitor in the presence of alkaline and oxidative degradation products using smart spectrophotometric and chemometric methods, J Pharmaceutical Anal. 2013;4:132–43. https://doi.org/10.1016/j.jpha.2013;9:1-6.
Riahi PS, Hadiloo F, Mohammad S, Milani R. A new technique for spectrophotometric determination of pseudoephedrine and guaifenesin in syrup and synthetic mixture, Drug Test Anal. 2011;3:319–324. https://doi.org/10.1002/dta.235.
Abdelazim AH, Shahin M, Abu-khadra AS. Application of different chemometric assisted models for spectrophotometric quantitative analysis of velpatasvir and sofosbuvir, Spectrochim. Acta - Part A Mol Biomol Spectrosc. 2021;252:119540. https://doi.org/10.1016/j.saa.2021.119540.
Zeid AM, Abdelazim AH, Shahin M. Simultaneous spectrophotometric quantitative analysis of elbasvir and grazoprevir using assisted chemometric models. Spectrochim Acta - Part A Mol Biomol Spectrosc. 2021;252:119505. https://doi.org/10.1016/j.saa.2021.119505.
Brereton RG. Multilevel multifactor designs for multivariate calibration, Analyst. 1997;122:1521–1529. https://doi.org/10.1039/a703654j.
Hegazy MA, Eissa MS, Abd El-Sattar OI, Abd El-Kawy M, Two and three way spectrophotometric-assisted multivariate determination of linezolid in the presence of its alkaline and oxidative degradation products and application to pharmaceutical formulation, Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2014;128:231–42. https://doi.org/10.1016/j.saa.2014.02.140
Abd El-Hadi HR, Eissa MS, Zaazaa HE, Eltanany BM. Chemometric quality assessment of doxylamine succinate with its degradation product: implementation of two predictive models on UV-spectrophotometric data of anti-emetic binary mixture. J AOAC Int. 2022. https://doi.org/10.1093/jaoacint/qsac090.
Darweish E, Marzouk HM, Fayez YM, Eissa MS. Advanced spectrophotometric resolution techniques for a spectrally overlapping spasmolytic binary mixture along with dichloroaniline as a toxic impurity: application to content uniformity testing. J AOAC Int. 2022;106:14–25. https://doi.org/10.1093/jaoacint/qsac092.
Thomas EV, Haaland DM. Comparison of multivariate calibration methods for quantitative spectral analysis. Anal Chem. 1990;62:1091–9. https://doi.org/10.1021/ac00209a024.
Antunes RT, Simão JE. Multivariate curve resolution of overlapping voltammetric peaks: quantitative analysis of binary and quaternary metal mixtures. Analyst. 2002;127:809–17.
El-Ragehy NA, Yehia AM, Hassan NY, Tantawy MA, Abdelkawy M. Chemometrics tools in detection and quantitation of the main impurities present in aspirin/dipyridamole extended-release capsules. J AOAC Int. 2016;99:948–56. https://doi.org/10.5740/jaoacint.16-0082.
Farid JF,Mostafa NM, Fayez YM,Essam HM, ElTanany BM. Chemometric quality assessment of paracetamol and phenylephrine hydrochloride with paracetamol impurities; comparative UV-spectrophotometric implementation of four predictive models, Spectrochim. Acta - Part A Mol. Biomol. Spectrosc. 2022; 265:120308. https://doi.org/10.1016/j.saa.2021.120308.
Shaaban H, Mostafa A, Al-zahrani B, Al-jasser B, Al-ghamdi R. Simultaneous determination of drugs affecting central nervous system in bulk and pharmaceutical formulations using multivariate curve resolution-alternating least squares. J Anal Methods Chem. 2020;2020:1–8.
Windig JG. Interactive self-modeling mixture analysis. Anal Chem. 1991;63:1425–32.
Gałuszka A, Migaszewski Z, Namieśnik J. The 12 principles of green analytical chemistry and the significance mnemonic of green analytical practices. Trends Anal Chem. 2013;50:78–84. https://doi.org/10.1016/j.trac.2013.04.010.
Tobiszewski M, Green chemistry metrics with special reference to green analytical chemistry, Molceuls. 2015; 20:10928–10946. https://doi.org/10.3390/molecules200610928.
Bahgat EA , Hashem H, Saleh H , Kamel EB , Eissa MS, Manipulation and processing of spectral signals for the assay of the newly authorized mixture of bupivacaine/meloxicam using fully green solvents and a comparative green evaluation supporting the greenness and sustainability of the developed smart spectrophotometric methods. J AOAC Int. 2023. https://doi.org/10.1093/jaoacint/qsad029.
Abd El-Hadi HR, Eltanany BM, Zaazaa HE, Eissa MS. HPLC-DAD approach for determination of pyridoxine hcl and doxylamine succinate in pure and pharmaceutical dosage forms: a Green stability-indicating assay method. Microchem J. 2021;172:106982. https://doi.org/10.1016/j.microc.2021.106982.
Kannaiah KP, Sugumaran A, Chanduluru HK, Rathinam S. Environmental impact of greenness assessment tools in liquid chromatography. Microchem J. 2021;170:106685. https://doi.org/10.1016/j.microc.2021.106685.
El-hadi HR, Eltanany BM, Zaazaa HE, Eissa MS. Chromatographic impurity profile assessment of dual action binary combination: ecological analysis with comparative statistics. Sustain Chem Pharm. 2023;33:101075. https://doi.org/10.1016/j.scp.2023.101075
Beebe KR, Pell RJ. Chemometrics: a practical guide, Wiley- Interscience, 1998.
Acknowledgements
Egyptian International Pharmaceutical Industries Co. (Cairo, Egypt) has provided the authors with pure triamterene and xipamide samples, for which they are grateful.
Funding
Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB). This work wasn’t funded by any third party.
Author information
Authors and Affiliations
Contributions
HA: carried out sample preparation, analysis, and writing the draftof manuscript.ME: supervised analysis procedures, reviewing all results and the draft ofmanuscript.HZ: planned, supervised the study and approved the final manuscript.BE: supervised analysis procedures, reviewing all results and the draft ofmanuscript. All authors read and approved the final manuscript.
Corresponding authors
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
The authors affirm that they are not knowledgeable of any financial or personal conflicts that would have seemed to have an impact on the study described in this work.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Abd El-Hadi, H.R., Eissa, M.S., Zaazaa, H.E. et al. Univariate versus multivariate spectrophotometric data analysis of triamterene and xipamide; a quantitative and qualitative greenly profiled comparative study. BMC Chemistry 17, 47 (2023). https://doi.org/10.1186/s13065-023-00956-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s13065-023-00956-9