Adjusted green spectrophotometric determination of favipiravir and remdesivir in pharmaceutical form and spiked human plasma sample using different chemometric supported models

Abstract

The environmentally friendly design of analytical methods is gaining interest in pharmaceutical analysis to reduce hazardous environmental impacts and improve safety and health conditions for analysts. The adaptation and integration of chemometrics in the development of environmentally friendly analytical methods is strongly recommended in the hope of promising benefits. Favipiravir and remdesivir have been included in the COVID-19 treatment guidelines panel of several countries. The main objective of this work is to develop green, tuned spectrophotometric methods based on chemometric based models for the determination of favipiravir and remdesivir in spiked human plasma. The UV absorption spectra of favipiravir and remdesivir has shown overlap to some extent, making simultaneous determination difficult. Three advanced chemometric models, classical least squares, principal component regression, and partial least squares, have been developed to provide resolution and spectrophotometric determination of the drugs under study. A five-level, two-factor experimental design has been used to create the described models. The spectrally recorded data of favipiravir and remdesivir has been reviewed. The noise region has been neglected as it has a negative impact on the significant data. On the other hand, the other spectral data provided relevant information about the investigated drugs. A comprehensive evaluation and interpretation of the results of the described models and a statistical comparison with accepted values have been considered. The proposed models have been successfully applied to the spectrophotometric determination of favipiravir and remdesivir in pharmaceutical form spiked human plasma. In addition, the environmental friendliness of the described models was evaluated using the analytical eco-scale, the green analytical procedure index and the AGREE evaluation method. The results showed the compliance of the described models with the environmental characteristics.

Peer Review reports

Introduction

The environmentally friendly design of analytical methods is gaining interest in pharmaceutical analysis to reduce hazardous environmental impacts and improve safety and health conditions for analysts. Application of chemometrics in green methods development is still limited. The adaptation and integration of chemometrics in green analytical method development is highly recommended with hoping for promising benefits [1, 2]. In general, chemometric tools provide feasibility to decrease data dimensionality and assign the irrelevant variables or objects as well as eliminate the irrelevant variables. Furthermore, chemometrics introduce unique possibility to whole data set treating as a group of nonrelated variables of objects [3]. Chemometrics can be applied in analytical procedure development targeting materials and energy savings and the minimization of the procedure’s environmental impact that directly refer to the procedure’s greenness [4].

Favipiravir [FV], Fig. 1a, is a purine nucleic acid analog with known antiviral activity considered in many infections. FV is activated to the phosphorribosylated and delivers activity via inhibition of RNA-dependent RNA polymerase [5]. Numerous clinical studies have demonstrated the effectiveness of FV in the treatment of COVID-19 [6, 7]. Previous research has described some analytical methods for the determination of FV, including HPLC methods [8, 9] and electrochemical method [10].

Remdesivir [RV], Fig. 1b, is a nucleotide prodrug of an adenosine analog. RV exerts its activity by binding to viral RNA-dependent RNA polymerase and subsequently inhibiting viral replication by premature termination of RNA transcription. RV has confirmed activity against COVID-19. The FDA has approved the use of RV for the treatment of COVID-19 in hospitalized adult and pediatric patients [11,12,13]. Previous research has described some analytical methods for the determination of RV, including HPLC methods [14, 15] and spectrophotometric methods [15, 16].

In fact, FV and RV were listed in the COVID-19 treatment guidelines of several countries. They were prescribed simultaneously for COVID-19, so it is highly recommended to develop an analytical method that allows the determination of FV and RV in biological samples. Few analytical methods were developed for determination of FV and RV in their binary mixture including TLC-densitometric method [17] and fluorescence-based analytical method [18].

Fig. 1
figure 1

Structural formula of FV (a) and RV (b)

In this article, adopted spectrophotometric determination of FV and RV was developed and applied for pharmaceutical form and spiked human plasma using several chemometrically assisted models. Three advanced chemometric models, the classical least squares [CLS], principal component regression [PCR], and partial least squares [PLS] methods [19, 20] were constructed and optimized for the integrated green spectrophotometric determination of the studied drugs. Greenness evaluation of the described models was done using different tools, the analytical eco-scale [21], the green analytical procedure index [22] and the AGREE evaluation method [23]. The described models showed superiority and agreement with the greenness characteristics in terms of the common green metric values. The authors hope to provide a promising challenge for achieving green goals by integrating chemometric tools and applying them with green assessment metrics.

Experimental

Materials and solvents

Pure powders of FV (99.10%), RDV (99.62%) were supplied by Benchmark Health Company, Cairo, Egypt. Drug-free human plasma of healthy volunteers was supplied by Blood Bank, Al-Azhar University Hospital, Damietta, Egypt. Remdesivir® vials [100 mg RV] and Anviziram® tablets [200 mg FV] were kindly purchased from local market. Ethanol, was procured from Sigma-Aldrich, Germany.

Apparatus and software

Shimadzu UV-Visible 1650 Spectrophotometer, Tokyo, Japan. UV-Probe personal spectroscopy software version 2.1. (Shimadzu). PLS model was implemented in Matlab R2013b (8.2.0.701) and manipulated by PLS toolbox software version 2.1, was accessed by Umm Al-Qura University, Makkah, Saudi Arabia.

Standard solutions

Standard stock solutions of FV (100 µg/mL) and RD (100 µg/mL) was prepared by dissolving 10 mg of each pure powder in 50 mL of ethanol, and the volume was made up to 100 mL with ethanol.

Procedures

CLS, PCR and PLS models design

Calibration and validation sets were created using the common approach, five-level two factorial design. Twenty-five mixtures of FV and RD were initially constructed and divided into two defined sets, calibration and validation sets. These mixtures were prepared by transferring different volumes of FV and RD from the standard stock solutions (100 µg/mL) into 10 mL volumetric flasks. The prepared solutions were adjusted to the mark with ethanol. The absorbance spectra of the prepared samples were scanned over the wavelength range 220–400 nm with an interval of 1 nm. CLS, PCR and PLS models were processed by transferring the spectral data into Matlab R2013b (8.2.0.701). Thirteen samples were used as calibration set and twelve samples were used as validation set. The predictability of the CLS, PCR and PLS was evaluated. In general, all described procedures were performed in accordance with relevant guidelines and regulations.

Procedures for the determination of the pharmaceutical dosage forms

Ten Anviziram® tablets were scratched, weighed, and finely powdered. An appropriate weight of powder corresponding to one tablet was placed in a 100 mL volumetric flask and the volume was made up to 50 mL with ethanol. The solution was shaken vigorously for 30 min and filtered. The volume was made up to the mark with ethanol to prepare a stock solution containing 2 mg/mL FV. Different concentrations were prepared and determined regarding to the procedures of the mentioned models.

Five Remdesivir® vials were weighed and an equivalent weight to one vial was transferred to a 100-mL volumetric flask and the volume made up to 50 mL with ethanol. The solution was shaken for 30 min and filtered. The volume was completed to 100 mL with ethanol to prepare a stock solution containing 1 mg/mL RV. Different concentrations were prepared and determined regarding to the procedures of the mentioned models.

Procedure for determination of FV and RD in spiked human plasma

Different spiked human plasma samples, considering that the mean plasma Cmax for FV (4.43 µg/mL) and the mean plasma Cmax for RV (3.027 µg/mL) [24, 25] and the proposed models linearity and detection limits allowed this level of determination, were developed by transferring aliquots of different concentrations from FV and RV working solutions to a series of 10-mL centrifugation tubes together with 1 mL of human plasma and 3 mL of acetonitrile. The tubes were shaken for 1 min on a vortex mixer and centrifuged for 30 min. The formed supernatants were evaporated to dryness. The residues were dissolved in appropriate volume of ethanol, transferred to 10-mL volumetric flasks together with 3 mL of acetate buffer pH 4 and diluting to volume with ethanol. The samples were determined using the described procedures.

Results and discussion

The integration and adaptation of chemometrics with spectrophotometric analysis represents a promising tool for achieving green chemical analysis. Since spectrophotometry is widely used in pharmaceutical quantitative analysis, researchers have developed many models for processing spectral data and enabling the determination of multiple components. In recent decades, CLS, PCR, and PLS models have been widely used for spectrophotometric analysis. In this work, the mentioned models were used for processing spectral data of FV and RV and allowed their determination in pharmaceutical form and spiked human plasma.

Solvent choice regarding to green ranking

Recently, the choice of solvent is strongly recommended considering the health and environmental aspects of organic solvents. Solvent selection was based on the ranking of solvents with respect to green analytical chemistry metrics [26]. Our strategy was to reduce the impact of hazardous solvents and replace commonly used organic solvents such as acetonitrile and methanol, with greener ones. So far, ethanol was the appropriate alternative organic solvent.

Models implementation for spectral data processing of FV and RV

The UV absorption spectra of FV and RV, Fig. 2, overlap to some extent, making simultaneous determination difficult. To solve this problem, the described models were implemented. First, the assignment of calibration and validation sets was performed using the statistical design for generating the design sets of the recommended experiments. This step was based on the optimization approach with five-level, two-factor experimental design [27]. This optimization step provided organized defined mixtures of FV and RV. Twenty-five sample mixtures, Table 1, were prepared, spectrally scanned, Fig. 3, and divided into two groups. Thirteen samples were used to develop a calibration set. In addition, twelve samples were used to test the predictive power of the described models. When selecting drug concentrations for the model study, it was recommended to test the linearity range of FV and RV. The commercial concentration of the drugs should also be considered in the model construction. The spectral data of FV and RV were divided into two parts: Noise and Information. Noise was excluded because it represented non informative data. This data part was neglected because it had a negative impact on the significant data. The other spectral data, on the other hand, contained the relevant information of the samples studied.

Fig. 2
figure 2

Absorption spectra of FV (9 µg/ mL), RV (9 µg/ mL) and their mixture (9 µg/ mL + 9 µg/ mL)

Table 1 Five-level, two-factor experimental design developed to create the described models
Fig. 3
figure 3

The absorption spectra of twenty-five mixtures of FV and RV planning mixtures

CLS was the model described, which recommended that all compounds in calibration samples be detected. PCR, on the other hand, allowed the determination of the compounds FV and RV even in the presence of interfering compounds. This feature gave the PCR model the preference over the CLS model. Cross-validation was developed for PCR, omitting one sample at a time. The plot of the root mean square error of cross-validation [RMSECV] of the results of the calibration set as a function of the number of latent variables [LVs] used to develop the PCR model for the samples FV and RV samples was shown in Fig. 4. PLS offered many advantages over CLS and PCR. PLS provided analysts with complete information about the spectral data as well as the concentrations of the compounds under investigation. This improved the quality and predictive power of PLS. The RMSECV plots of the results of the calibration set as a function of the number of LVs used to build the PLS model for the samples of FV and RV are shown in Figs. 5, 6.

Fig. 4
figure 4

RMSECV plot of the calibration set results as a function of the number of LVs applied to develop the PCR model of FV and RV mixtures

Fig. 5
figure 5

RMSECV plots of the calibration set results as a function of the number LVs applied to develop the PLS model of FV in FV and RV mixtures

Fig. 6
figure 6

RMSECV plots of the calibration set results as a function of the number LVs applied to develop the PLS model of RV in FV and RV mixtures

The evaluation and interpretation of the described model data was achieved. The evaluation of the obtained data and the statistical comparison with the accepted values were also considered. The percentage recoveries, the mean, the standard deviation [SD], the root mean square error of calibration [RMSEC] and the root mean square error of prediction [RMSEP] were listed in Tables 2 and 3.

Table 2 Results of the described models for the calibration set of FV and RV mixtures
Table 3 Results of the described models for the validation set of FV and RV mixtures

Methods validation

The models described was validated regarding to linearity range, accuracy, precision, limits of detection [LOD], limits of quantitation [LOQ] and selectivity parameters.

Linearity range

Regarding to the developed experimental design which considered the range of 1–17 µg/mL for FV and RDV, accepted results were obtained over this concentration range as listed in Table 4.

Table 4 Performance and validation data of the described models for determination of FV and RV

LOD and LOQ

LOD and LOQ were calculated based on the residual standard deviation of the considered linearity range (SD) and the slope using the following equations:

$$\text{LOD}=3.3\,\text{SD}/\text{slope}$$
$$\text{LOQ}=10\,\text{SD}/\text{slope}$$

The results obtained, Table 4, revealed the sensitivity of the described models.

Accuracy

The accuracy of the developed models was monitored by calculating the mean percent recovery (%R), for triplicate determination of three concentration levels of each drug (4, 8, and 16 µg/mL). The accepted percent of recovery as listed in Table 4 demonstrated the high reliability of the developed models.

Precision

The precision of the developed models was monitored by calculating the percent of relative standard deviation (%RSD), for triplicate determination of three concentration levels of each drug (4, 8, and 16 µg/mL) within one day for repeatability and on three successive days for Inter mediate precision. The small values of %RSD demonstrated high precision of the proposed models as listed in Table 4.

Selectivity

The models selectivity was achieved by selective estimation of FV or RDV in the pharmaceutical form of each drug through application of standard addition technique. The results listed in Table 5 revealed that the models were sufficient selective for determination of the drugs under the study without interference from pharmaceutical excipients.

Table 5 Standard addition technique data for FV and RV using the described models

Application of the proposed models for determination of FV and RV pharmaceutical dosage forms

The described models were successfully applied to determine FV and RV in the pharmaceutical dosage forms. The results were statistically compared with those obtained by the reported method of FV [8] and RV [14]. By applying statistical tests, no significant differences were found at 95% confidence level, assuring the reliability of the described models for determination of FV and RV in the pharmaceutical dosage forms, Table 6.

Table 6 Determination of FV and RV in pharmaceutical tablets by described model and statistical comparison with previous reported methods

Determination of FV and RV in spiked human plasma

CLS, PCR and PLS models were successfully applied for the determination of FV and RV in spiked human plasma as they provided a high degree of linearity and detection which allowed the determination of FV, the mean plasma Cmax for FV (4.43 µg/mL) and RV, the mean plasma Cmax for RV (3.027 µg/mL) [24, 25]. The data in Table 7 showed that the described models were suitable for the determination of the studied drugs in human plasma without interference of endogenous components of the plasma matrix.

Table 7 Determination of FV, RV in spiked human plasma by the proposed models

Green assessment of the described models

To evaluate and rank the greenness of the described models, analytical eco-scale score [21] was measured mainly depending on the amounts of solvents consumed. The analytical eco-scale is a semi quantitative metric considered that ideal green analysis has a value of 100. Penalty points were assigned for every analytical procedure parameter including amount of reagents, hazards, energy and waste, deviated from ideal green analytical chemistry principles. The penalty points of full procedure parameters were summed and subtracted from the basis of 100. It was reported that score more than 75 reveled excellent green analysis, score less than 50 score indicated inadequate green analysis, and score between 50 and 75 revealed acceptable green analysis. As the calculated scores were 79, 81 and 78 for CLS, PCR and PLS respectively these scores revealed the green excellence of the described models and had minimal negative impact on the environment and human health.

Furthermore, green analytical methods index introduces precise tool for view of different variables included in the analytical procedure. It considered sample preparation, sample handling (collection, preservation, transport and storage) as well as the chemicals used and the instrumentation. Every variable was colored from green to yellow to red which indicated either low, medium or high negative environmental impact, respectively [22]. The described models CLS, PCR, PLS had the 5 green zones and one red zone.

Finally, the analytical greenness measure (AGREE) tool was used, which presents the environmental friendliness profile of the analytical methods as a numerical value. AGREE is a user-friendly software that uses the twelve-significance principle of green analytical chemistry as input criterion. Each of the twelve inputs was scored according to range from 0 to 1 and mirrored on the intuitive red-yellow-green color scale. The weight of every input criterion was assigned according to its role in the procedure, and this was reflected by the width of its corresponding segment. The output was a clock-like graph, with an overall score and color representation in the middle [23]. The obtained ultimate score was 0.82, 0.84, 0.80 for CLS, PCR and PLS respectively. These results confirmed the superior green characters of the developed models. AGREE tool takes into account the quantities of any reagent used. It is easy to construct and shows the weaknesses of the studied method. In summary, the results of the green metrics presented a detailed environmental friendliness profile and confirmed compliance with environmentally friendly practices in most cases [28,29,30,31,32,33,34]. The green assessment results were presented in Table 8.

Table 8 Green assessment results of the proposed chemomertric models

Advantages of the models described over the previous reported methods

The present work demonstrated the feasibility of green fitted CLS, PCR and PLS chemometric based models for simultaneous spectroscopic determination of FV and RV in the pure form, pharmaceutical dosage and spiked human plasma. They were applied in the spectra data evaluation providing the synchronous inclusion of many wavelengths rather than using a single wavelength. This greatly increases the precision ability of the analysis process. The described models provided some advantages compared to the conventional methods as they were non-destructive and performed directly to samples without any extraction procedures, unnecessary performing stability studies. and cost-effective. Moreover, the analysis time of the developed models was shorter and the solvent consumption was much lower than previous reported works.

Conclusion

Adjusted green fitted spectrophotometric models, classical least squares, principal component regression, and partial least squares were developed for the determination of favipiravir and remdesivir in pharmaceutical form and spiked human plasma. The chemometric models were constructed and optimized for integrated green spectrophotometric determination of the studied drugs. Greenness evaluation of the described models was done using, the analytical eco-scale, the green analytical procedure index and the AGREE evaluation method. The results showed that the described models complied and met the environmental friendliness characteristics in terms of the official green metric values. The results confirmed the minimal impact of the developed models on the environment and the general health of the analysts. The models offered successful feasibility for the spectrophotometric determination of favipiravir and remdesivir in spiked human plasma.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

FV:

Favipiravir

RV:

Remdesivir

CLS:

Classical least squares

PCR:

Principal component regression

PLS:

Partial least squares

References

  1. Pérez RL, Escandar GM. Experimental and chemometric strategies for the development of Green Analytical Chemistry (GAC) spectroscopic methods for the determination of organic pollutants in natural waters. Sustain Chem Pharm. 2016;4:1–12.

    Article  Google Scholar 

  2. Kalinowska K, Bystrzanowska M, Tobiszewski M. Chemometrics approaches to green analytical chemistry procedure development. Curr Opin Green Sustain Chem. 2021;30:100498.

    Article  CAS  Google Scholar 

  3. Brereton RG, Jansen J, Lopes J, Marini F, Pomerantsev A, Rodionova O, et al. Chemometrics in analytical chemistry—part II: modeling, validation, and applications. Anal Bioanal Chem. 2018;410(26):6691–704.

    Article  CAS  PubMed  Google Scholar 

  4. Koel M. In: Kaljurand M, editor. Green analytical chemistry. 2nd ed. Royal society of Chemistry; 2019.

  5. Goldhill DH, Te Velthuis AJ, Fletcher RA, Langat P, Zambon M, Lackenby A, et al. The mechanism of resistance to favipiravir in influenza. Proc Natl Acad Sci. 2018;115(45):11613–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  6. Hassanipour S, Arab-Zozani M, Amani B, Heidarzad F, Fathalipour M, Martinez-de-Hoyo R. The efficacy and safety of Favipiravir in treatment of COVID-19: a systematic review and meta-analysis of clinical trials. Sci Rep. 2021;11(1):1–11.

    Article  Google Scholar 

  7. Mirtaleb MS, Mirtaleb AH, Nosrati H, Heshmatnia J, Falak R, Emameh RZ. Potential therapeutic agents to COVID-19: an update review on antiviral therapy, immunotherapy, and cell therapy. Biomed Pharmacother. 2021;138:111518.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Bulduk İ. HPLC-UV method for quantification of favipiravir in pharmaceutical formulations. Acta Chromatographica. 2021;33(3):209–15.

    Article  CAS  Google Scholar 

  9. Marzouk HM, Rezk MR, Gouda AS, Abdel-Megied AM. A novel stability-indicating HPLC-DAD method for determination of favipiravir, a potential antiviral drug for COVID-19 treatment; application to degradation kinetic studies and in-vitro dissolution profiling. Microchem J. 2022;172:106917.

    Article  CAS  PubMed  Google Scholar 

  10. Allahverdiyeva S, Yunusoğlu O, Yardım Y, Şentürk Z. First electrochemical evaluation of favipiravir used as an antiviral option in the treatment of COVID-19: a study of its enhanced voltammetric determination in cationic surfactant media using a boron-doped diamond electrode. Anal Chim Acta. 2021;1159:338418.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  11. Ferner RE, Aronson JK. Remdesivir in covid-19. London: British Medical Journal Publishing Group; 2020.

    Book  Google Scholar 

  12. Norrie JD. Remdesivir for COVID-19: challenges of underpowered studies. Lancet. 2020;395(10236):1525–7.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  13. McCreary EK, Angus DC. Efficacy of remdesivir in COVID-19. JAMA. 2020;324(11):1041–2.

    Article  CAS  PubMed  Google Scholar 

  14. Ibrahim AE, Deeb SE, Abdelhalim EM, Al-Harrasi A, Sayed RA. Green Stability Indicating Organic Solvent-Free HPLC determination of Remdesivir in Substances and Pharmaceutical Dosage Forms. Separations. 2021;8(12):243.

    Article  CAS  Google Scholar 

  15. Bulduk I, Akbel E. A comparative study of HPLC and UV spectrophotometric methods for remdesivir quantification in pharmaceutical formulations. J Taibah Univ Sci. 2021;15(1):507–13.

    Article  Google Scholar 

  16. Abdelazim AH, Ramzy S. Spectrophotometric quantitative analysis of remdesivir using acid dye reagent selected by computational calculations. Spectrochim Acta Part A Mol Biomol Spectrosc. 2022;276:121188.

    Article  CAS  Google Scholar 

  17. Noureldeen DA, Boushra JM, Lashien AS, Hakiem AFA, Attia TZ. Novel environment friendly TLC-densitometric method for the determination of anti-coronavirus drugs “Remdesivir and Favipiravir”: Green assessment with application to pharmaceutical formulations and human plasma. Microchem J. 2022;174:107101.

    Article  CAS  PubMed  Google Scholar 

  18. El-Awady M, Elmansi H, Belal F. Insights on the quantitative concurrent fluorescence-based analysis of Anti-COVID-19 drugs Remdesivir and Favipiravir. J Fluoresc. 2022;32(5):1941–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  19. Attia KA, El-Abasawi NM, El-Olemy A, Abdelazim AH. Simultaneous spectrophotometric determination of Elbasvir and Grazoprevir in a pharmaceutical preparation. J AOAC Int. 2018;101(2):394–400.

    Article  CAS  PubMed  Google Scholar 

  20. Attia KA, El-Abasawi NM, El-Olemy A, Abdelazim AH. Application of different spectrophotometric methods for simultaneous determination of elbasvir and grazoprevir in pharmaceutical preparation. Spectrochim Acta Part A Mol Biomol Spectrosc. 2018;189:154–60.

    Article  CAS  Google Scholar 

  21. Gałuszka A, Migaszewski ZM, Konieczka P, Namieśnik J. Analytical Eco-Scale for assessing the greenness of analytical procedures. TRAC Trends Anal Chem. 2012;37:61–72.

    Article  Google Scholar 

  22. Płotka-Wasylka J. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index. Talanta. 2018;181:204–9.

    Article  PubMed  Google Scholar 

  23. Pena-Pereira F, Wojnowski W, Tobiszewski M. AGREE—Analytical GREEnness metric approach and software. Anal Chem. 2020;92(14):10076–82.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  24. Madelain V, Nguyen THT, Olivo A, De Lamballerie X, Guedj J, Taburet A-M, et al. Ebola virus infection: review of the pharmacokinetic and pharmacodynamic properties of drugs considered for testing in human efficacy trials. Clin Pharmacokinet. 2016;55(8):907–23.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  25. Deb S, Reeves AA, Hopefl R, Bejusca R. ADME and pharmacokinetic properties of remdesivir: its drug interaction potential. Pharmaceuticals. 2021;14(7):655.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  26. Prat D, Hayler J, Wells A. A survey of solvent selection guides. Green Chem. 2014;16(10):4546–51.

    Article  CAS  Google Scholar 

  27. Brereton RG. Multilevel multifactor designs for multivariatecalibration. Analyst. 1997;122(12):1521–9.

    Article  CAS  Google Scholar 

  28. Abdelazim AH, Abourehab MA, Abd Elhalim LM, Almrasy AA, Ramzy S. Green adherent spectrophotometric determination of molnupiravir based on computational calculations; application to a recently FDA-approved pharmaceutical dosage form. Spectrochim Acta Part A Mol Biomol Spectrosc. 2023;285:121911.

    Article  CAS  Google Scholar 

  29. Abdelazim AH, Abourehab MA, Abd Elhalim LM, Almrasy AA, Ramzy S. Different spectrophotometric methods for simultaneous determination of lesinurad and allopurinol in the new FDA approved pharmaceutical preparation; additional greenness evaluation. Spectrochim Acta Part A Mol Biomol Spectrosc. 2022;285:121868.

    Article  Google Scholar 

  30. Abourehab M, Shahin M, Sheikh R, Ellateif A, Fawzi S, Gouda A. Utilization of N-bromosuccinimide for the sensitive spectrophotometric determination of pipazethate HCl as antitussive drug in pure and dosage forms. Annales Pharmaceutiques Françaises. 2021;79(6):652–63.

    Article  CAS  PubMed  Google Scholar 

  31. Kassem MA, Guesmi NE. Sensitive kinetic spectrophotometric determination of Cyclobenzaprine Hcl in pure form and pharmaceutical formulations. Anal Chem Lett. 2016;6(5):657–68.

    Article  CAS  Google Scholar 

  32. Gouda A, Hamdi A, El Sheikh R, Abd Ellateif A, Badahdah N, Alzuhiri M, et al. Development and validation of spectrophotometric methods for estimation of antimigraine drug eletriptan hydrobromide in pure form and pharmaceutical formulations. Annales Pharmaceutiques Françaises. 2021;79(4):395–408.

    Article  CAS  PubMed  Google Scholar 

  33. Garoub MM, Gouda AA, ElSheikh R, Fawzy E, ElToukhi WE. Utilization of cloud point extraction for enhancement the efficiency of spectrophotometric estimation of milnacipran HCl as anti-depression drug in dosage forms and application to its tablets uniformity testing. J Umm Al-Qura Univ Appl Sci. 2022;9:1–11.

    Google Scholar 

  34. Hameed AM. An eco-friendly ultrasound-assisted deep eutectic solvent-based liquid–phase microextraction method for enrichment and quantification of nickel in environmental samples. J Umm Al-Qura Univ Appl Sci. 2022;8:1–12.

    Google Scholar 

Download references

Acknowledgements

The authors would like to thank the Deanship of Scientific Research at Shaqra University for supporting this work.

Funding

This work was funded by the Deanship of Scientific Research at Shaqra University for supporting this work.

Author information

Authors and Affiliations

Authors

Contributions

MSI: Review and editing. AHA: Investigation, methodology and writing—original draft. ASB: Review and editing. SR: Methodology and data curation. MG: Review and editing. SA: Data analysis. AMZ: Writing, review and editing. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Ahmed H. Abdelazim.

Ethics declarations

Ethics approval and consent to participate

This work was approved by the Committee of Research Ethics in the Faculty of Pharmacy, Al-Azhar University, Cairo, Egypt. All participants signed informed consent statement before participation in the study. All described procedures were performed in accordance with relevant guidelines and regulations.

Consent for publication

Written informed consents were obtained from the participants for publication of this report.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Imam, M.S., Abdelazim, A.H., Ramzy, S. et al. Adjusted green spectrophotometric determination of favipiravir and remdesivir in pharmaceutical form and spiked human plasma sample using different chemometric supported models. BMC Chemistry 17, 89 (2023). https://doi.org/10.1186/s13065-023-01001-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13065-023-01001-5

Keywords