Skip to main content
  • Research article
  • Open access
  • Published:

Time-dependent integrity during storage of natural surface water samples for the trace analysis of pharmaceutical products, feminizing hormones and pesticides

Abstract

Monitoring and analysis of trace contaminants such as pharmaceuticals and pesticides require the preservation of the samples before they can be quantified using the appropriate analytical methods. Our objective is to determine the sample shelf life to insure proper quantification of ultratrace contaminants. To this end, we tested the stability of a variety of pharmaceutical products including caffeine, natural steroids, and selected pesticides under refrigerated storage conditions. The analysis was performed using multi-residue methods using an on-line solid-phase extraction combined with liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS) in the selected reaction monitoring mode. After 21 days of storage, no significant difference in the recoveries was observed compared to day 0 for pharmaceutical products, while for pesticides, significant losses occurred for DIA and simazine after 10 days (14% and 17% reduction respectively) and a statistically significant decrease in the recovery was noted for cyanazine (78% disappearance). However, the estrogen and progestogen steroids were unstable during storage. The disappearance rates obtained after 21 days of storage vary from 63 to 72% for the feminizing hormones. Overall, pharmaceuticals and pesticides seem to be stable for refrigerated storage for up to about 10 days (except cyanazine) and steroidal hormones can be quite sensitive to degradation and should not be stored for more than a few days.

Introduction

The simple way to insure the integrity of collected samples would be to keep them refrigerated and analyze them within 24 h of collection before unwanted chemical, physical and biological alterations of the samples are observed. Unfortunately, those analyses are often dependent on heavily solicited mass spectrometry instruments and considering various logistical constraints, it is often impossible to analyze such samples within a day. Then the question arises: how long can we store those samples before we analyze them for ultra traces of contaminants (sometimes to concentration below the ng l-1 range).

To address this, we have performed simultaneous stability studies of pharmaceuticals (naproxen, gemfibrozil, carbamazepine, trimetroprim, caffeine), steroidal hormones both estrogens (estriol, estradiol, 17α-ethynilestradiol, estrone) and progestogens (norethindrone, medroxyprogesterone, progesterone, norgestrel) and pesticides (deethylatrazine (DEA), deisopropylatrazine (DIA), simazine, atrazine and cyanazine). The major characteristics of the investigated products are shown in Table 1.

Table 1 Target compounds, use, molecular weight (MW), pKa, water solubility and vapor pressure.

The main factors affecting the stability of analytes in water samples include hydrolysis, photolysis, physical adsorption or release to or from suspended particulates, chemical degradation by oxidative free-radicals such as alkylperoxy and hydroxyl radicals present in natural waters, or microbial degradation [1], the nature of the sample-container, solubility, vapor pressure and the conditions of storage (temperature, darkness, use of preservatives, time interval between sampling and analysis [2]). Also, the stability of the analytes can be linked to their vapor pressure and water solubility. Indeed, in the literature, it is reported that compounds having a low vapor pressure and medium water solubility (up to 40 mg L-1) are stable while poor stability is attributed to compounds having high water solubility (up to 700 mg L-1), or relatively high vapor pressure [3].

The most extensive stability studies found in the literature have focused on pesticides. Such research has confirmed that many pesticides are unstable in natural waters, depending on microbial degradation, hydrolysis and photolysis [46]. To compensate this lack of stability, various stabilizers or preservatives have been added to aqueous samples, e.g., methanol [7], dichloromethane, dilute acid solutions or HgCl2 [5] to retard the decomposition of the constituent chemicals. Studies on alternative pesticide stabilization techniques, including the use of freeze-drying, have been published. Again, the results showed that the stability of the compounds depends on their water solubility and vapor pressure.

Other papers have demonstrated that solid-phase extraction (SPE) is a good alternative for the storage of pesticides pre-concentrated from water samples [3, 8]. For example, de la Colina et al. [5] have indicated that storage of different pesticide classes on the C18 silica-gel surface of solid-phase cartridges for 30 days at 4°C or -18°C is effective for 17 out of the 23 pesticides studied. Sabik et al. [8] have shown that it is possible to preserve herbicides (e.g DEA, DIA, cyanazine, simazine and atrazine) and degradation products in large volumes of surface water, without physical, chemical or biological alteration of these compounds, by using GCB cartridges (large-particle-size Carbopack B 60-80 mesh). Although no major difference was reported between surface water conservation and cartridge storage for the selected herbicides. Nevertheless, many methods for the ultratrace analysis of pharmaceuticals and other emerging contaminants are trying to move away from off line solid-phase extractions and cartridges [9]; it is therefore even more pertinent to determine the procedural limits of how natural samples should be preserved when using an automated SPE system.

Few studies consider the stability of estrogens and progestogens in surface waters. Indeed, Baronti and co-workers [10] reported that the addition of 1% of formaldehyde to water samples seem to prolong the stability of estrogens. Except for estrone, a significant loss of estrogens occurred after 60 days of storage. In addition, it was demonstrated that formaldehyde added to water was able to slow but not definitively block bacterial activity [11]. Labadie and co-workers [12] suggested that formaldehyde (1%, v/v) must be added to the effluents samples immediately after collection. Furthermore, Vanderford et al [13] tested the preservation of samples for the trace analysis of 27 compounds including estrogens. The results showed that 1% of formaldehyde added to water was able to prolong estrogens stability but could affect the stability of other compounds. Therefore, those authors concluded that sulfuric acid is the most effective and least destructive preservative agent for their study.

However, it is essential to know how long the content of a sample may remain stable before analysis. In this context, the objective of this study was to provide data concerning the stability under normal operating conditions and variable time of storage for a suite of pharmaceutical and personal care products (PPCP), pesticides, estrogens and progestogens in natural surface waters. These compounds were selected based on their high consumption and their reported occurence in wastewater and drinking water sources [1416]. These compounds were analyzed by a multi-residue method using an on-line solid-phase extraction combined with liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS), with two ionization sources: ESI interface applied for analysis of pharmaceuticals and pesticides [14], while an APPI interface was applied for the analysis of steroids (estrogens and progestogens) [15].

Experimental

Reagents and chemicals

Analytical standards such as PPCP, pesticides and hormones were purchased as powders from Sigma-Aldrich Canada (Oakville, ON, Canada) (98-99% pure). Internal standards included [13C3]-estradiol, [13C3]-caffeine and [13C3]-atrazine and were supplied by ACP Chemical Inc. (Montréal, Qc, Canada). All solvents (trace analysis grade), 0.1% formic acid in water and LC-grade water were purchased from Baker (Quebec, Canada).

Standards solutions

Due to the solubility properties of these compounds in methanol, individual stock solutions of the analytes were initially prepared at 1000 mg l-1 by dissolving 25 mg of each compound in 25 ml of methanol and stored in the dark at -20°C. Standard mixtures of the compounds were prepared in methanol at different concentrations by appropriate dilutions of the individual stock solutions.

In order to increase the accuracy of the analytical data, stable isotopically-labeled standards were added to the initial water samples. [13C3]-atrazine served as the internal standard for the quantification of pesticides, [13C3]-caffeine for the quantification of pharmaceuticals and personal care products and finally [13C3]-estradiol served for the quantification of estrogens and progestogens.

Working solutions of the target compounds and internal standards were prepared in the matrix to build the calibration curve. The concentrations of the analytes ranged from 0 to 100 ng L-1 and the internal standards concentrations were set at 70 ng L-1.

Sampling and filtration

Homogeneous surface water samples (1l) were collected in January 2008 from one of Montreal drinking raw water intake. The characteristics of selected surface water are shown in Table 2.

Table 2 Characteristics of the surface water sample tested.

Storage studies

The stability of selected compounds in surface water was evaluated for storage in refrigerated amber glass bottles. For this purpose, the matrix samples obtained were filtered through a 0.45-μm PTFE membrane (Millipore) to remove particulate matter and other suspended solids, and then acidified.

Apparatus

On line SPE-LC-MS/MS Analysis

Briefly, the LC system consists of a binary pump (a Surveyor LC-pump) and a quaternary pump (Surveyor MS Pump Plus - Thermo Fisher Scientific, Waltham, MA, USA). A six-port switching valve was used for all analysis. The sample was injected using a Surveyor autosampler fitted with a 1-mL sample loop, through the valve into the extraction column (Hypersil GOLDTM column, 12 μm, 20 mm × 2.1 mm i.d). The extraction column was then loaded for 1.4 min (flow rate 1 ml min-1) with water/formic acid solution (pH 2.6). The valve position was then switched to allow the bound material to be eluted from the extraction cartridge in back flush mode directly onto the analytical column with 0.1% formic acid-methanol (95:5 v/v) at a flow rate of 200 μl min-1. After 17 min, the valve position was again switched to allow the extraction column to be re-equilibrated at a flow rate of 1 ml min-1 with water/formic acid solution (pH 2.6). The total run time per sample was 20 min for pharmaceuticals and pesticides and 15 min for steroidal hormones. The LC was performed using a 3-μm Hypersil GOLD column, 50 mm × 2.1 mm i.d. (Thermo Fisher Scientific, Waltham, MA, USA) preceded by a guard column (2 × 2 mm, 5 μm). The extraction and analytical columns were kept at ambient temperature. For estrogens and progestogens, the same procedural steps were carried out, except the analytical column temperature (40°C), and variations for the elution and separation gradients.

A TSQ Quantum Ultra AM Mass Spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) tandem triple quadrupole mass spectrometry fitted with either an ESI or APPI source was used for detection. The instrument was operated in positive ionization mode and was directly coupled to the HPLC system at a flow rate of 200 μl min-1. Sample analysis was performed in the selective reaction monitoring mode (SRM). System control and data acquisition was performed using the Analyst Xcalibur software (rev. 2.0 SP2, Thermo Fisher Scientific). Further methodological details are available [1416].

Statistical analysis

A one-way analysis of variance (ANOVA Tukey's-b post hoc) test was used to evaluate whether the means of control and experiment groups are statistically different. All treatments were carried out in triplicate, and data in Figure 1 are expressed as mean recoveries with relative standard deviations. Statistical analysis was performed using SPSS 13 software (SPSS Inc., Chicago, IL), significance was set at the P < 0.05 probability level.

Figure 1
figure 1

Effect of various storage periods on recovery (%) of pharmaceuticals, pesticides, hormones (synthetic and natural estrogens and progestogens) dissolved in surface water at 100 ng l-1 Level. The error bar lengths represent the relative standard deviations on mean recovery (recovery for three replicates). Bars with the same letters are not statistically different p > 0.05 level using a Tukey's-b post hoc test.

Quantification and data analysis

Standard solutions used for quantification were also preconcentrated using the same procedure as the samples. Before each analysis, the IS was added to correct for variation in sample recovery and instrumental performance. Peak areas of analytes were normalized to those of their IS. Five specific concentrations of native analytes ranged from 0 to 100 ng l-1 with a fixed addition at 70 ng l-1 of a stable isotopically-labeled standard injected for each analysis to build up a calibration curve (r2 values were at least >0.988). Areas of the analytes and IS were calculated using the LCquanTM 2.5 software (Thermo Fisher Scientific inc).

Results and discussion

Schwartz and co-workers [17] mentioned that bacteria cannot survive in organic solvents, to improve the stability of these target compounds in surface water samples, we added 2.5% of methanol to fresh working solutions previously acidified at pH 2.8 and spiked at 100 ng l-1 level.

Pharmaceutical and personal care products

For any pollutant, including pharmaceuticals, biotic transformations in surface waters may occur via hydrolysis and photolysis. Most pharmaceuticals are usually designed for oral intake and generally resistant to hydrolysis, so quite often, the primary pathway for their abiotic transformation in surface waters is direct or indirect photolysis [18].

During the storage stability study, the ANOVA statistical analysis shows that no significant losses were observed after 21 days of storage for all pharmaceutical and personal care products studied including carbamazepine, naproxen, gemfibrozil and caffeine over the entire period of storage in surface water at 40°C, the recoveries obtained ranged from 85 to 129% (Figure 1). The stability of these compounds can be probably attributed to their low vapor pressure and their medium water solubility (up to 40 mg l-1), both of these factors probably also contribute to the stability of many pesticides in surface waters [4].

Pesticides

The pesticides included in this study were tested at concentrations equal to 100 ng l-1, the maximum allowed by EU legislation [8]. It was demonstrated that the pesticides can be degraded during storage by such processes as hydrolysis or microbial decomposition. In order to evaluate optimum conditions for storing the pesticides in matrix water before analysis, different storage periods were studied.

Figure 1 shows that no statistically significant losses were observed for atrazine and its first degradation intermediate DEA after 21 days of storage under our experimental conditions, these results are in agreement with Aguilar et al. [19]. While significant losses of DIA and simazine were observed after 10 days of storage, there was only a 14% reduction for DIA and a 17% reduction for simazine. These results can probably be attributed (amongst others things), to the presence of H+ ions which contribute to degradation of these compounds by hydrolysis because it has been shown that at pH >4 (which we would normally expect to find in the aquatic environment) hydrolysis of simazine is negligible [20]. In addition, Lyytikäinen and co-workers have demonstrated that at pH 8 after 28 days of storage, 10% loss of simazine occurred in water [21].

In the case of cyanazine, high instability was detected over the whole duration of storage. This is not a surprise given the recognized sensitivity of cyanazine to hydrolysis in acidic medium which produces a carboxylic acid and another product from the cleavage of the secondary amine [22]. Cyanazine is also much less stable than atrazine and simazine in surface waters of the USA, and this has been attributed to the oxidation of the cyanazine [20]. Furthermore, the poor stability of cyanazine can also be attributed to its high water solubility, at up to 700 mg l-1 [3]. The chromatograms corresponding to the preconcentration of 1 ml of surface water sample spiked at 100 ng l-1 level with the pharmaceuticals and pesticides obtained after 21 days of storage at 40°C are given in Figure 2.

Figure 2
figure 2

SPE-LC-ESI-MS/MS SRM chromatograms of pharmaceuticals and pesticides obtained after 21 days of storage at 4°C in surface water (pH = 2.8) spiked at 100 ng l-1 level and with 2.5% of MeOH added.

Estrogens and progestogens

In the case of feminizing steroids, serious stability problems arise during sample storage in the environmental matrix. The ANOVA analysis shows that in surface water samples, all the estrogens and the progestogens present statistically significant losses varying from 63 to 72% after 10 days of storage (Figure 1).

No oxidation of estradiol (E2) to estrone (E1) was apparent given that the elimination rates are almost identical. These losses can be linked to the physicochemical properties of these compounds. Also, the disappearance from solution can alternatively be attributed to the adsorption of these compounds onto suspended particulate matter and this would therefore reduce their concentrations in the aqueous phase [23, 24] and would depend on matrix characteristics such as total organic carbon, turbidity and oxygen consumption. Figure 3 represents the chromatograms of these compounds detected after 3 days of storage in surface water samples.

Figure 3
figure 3

SPE-LC-APPI-MS/MS SRM chromatograms of estrogens and progestogens obtained after 3 days of storage at 4°Cin surface water (pH = 2.8) spiked at 100 ng l-1 and 2.5% of MeOH was added.

Conclusions

In conclusion, 'immediate analysis' is the best way to obtain the most accurate data, but in practice this is not always possible. Therefore, it is often necessary to store surface water samples before the quantification of pharmaceutical products, pesticides and steroidal hormones.

For pharmaceutical compounds and for most pesticides tested, the compounds are quite stable to degradation when quickly filtered, acidified and refrigerated. It seems feasible to store natural samples for up to three weeks without significant losses of analyte, except for cyanazine (and presumably other hydrolysis-prone compounds).

In the case of the steroidal hormones, both estrogens and progestogens, high instability and severe losses were observed during sample storage. Therefore, the degradation of these products is linked to their physico-chemical properties and the type of matrix. Because of this, we would recommend to analyse for steroidal hormones ideally within three days of collection and certainly within less than a 1 week, unless stability studies specific to the actual experimental conditions are verified.

References

  1. Hengel MJ, Mower CR, Shibamoto T: New method for analysis of pyrethroid insecticides: Esfenvalerate, cis-permethrin, and trans-permethrin, in surface waters using solid-phase extraction and gas chromatography. Bull Environ Contam Toxicol. 1997, 59: 171-178. 10.1007/s001289900461.

    Article  CAS  Google Scholar 

  2. Ferrer I, Barcelo D: Stability of pesticides stored on polymeric solid-phase extraction cartridges. J Chromatogr A. 1997, 778: 161-170. 10.1016/S0021-9673(97)00300-2.

    Article  CAS  Google Scholar 

  3. Barcelo D, Alpendurada MF: A review of sample storage and preservation of polar pesticides in water samples. Chromatographia. 1996, 42: 704-712. 10.1007/BF02267705.

    Article  CAS  Google Scholar 

  4. Casas V, Llompart M, Garcia-Jares C, Cela R, Dagnac T: Effects of sample pretreatment and storage conditions in the determination of pyrethroids in water samples by solid-phase microextraction and gas chromatography-mass spectrometry. Anal Bioanal Chem. 2007, 387: 1841-1849. 10.1007/s00216-006-1072-3.

    Article  CAS  Google Scholar 

  5. de la Colina C, Sanchez-Rasero F, Dios G, Romero E, Pena A: Effect of storage on the recovery of different types of pesticides ssing a solid-phase extraction method. Analyst. 1997, 122: 7-11. 10.1039/a605275d.

    Article  CAS  Google Scholar 

  6. Mouvet C, Jeannot R, Riolland H, Maciag C: Stability of isoproturon, bentazone, terbuthylazine and alachlor in natural groundwater, surface water and soil water samples stored under laboratory conditions. Chemosphere. 1997, 35: 1083-1097. 10.1016/S0045-6535(97)00174-4.

    Article  CAS  Google Scholar 

  7. Berrueta LA, Gallo B, Vicente F: A review of solid phase extraction: Basic principles and new developments. Chromatographia. 1995, 40: 474-483. 10.1007/BF02269916.

    Article  CAS  Google Scholar 

  8. Sabik H, Jeannot R, Sauvard E: Stability of herbicides and their degradation products on graphitized carbon black extraction cartridges used for large volumes of surface water. Analysis. 2000, 28: 835-842. 10.1051/analusis:2000152.

    Article  CAS  Google Scholar 

  9. Segura PA, Gagnon C, Sauvé S: A fully automated on-line preconcentration and liquid chromatography-tandem mass spectrometry method for the analysis of anti-infectives in wastewaters. Anal Chim Acta. 2007, 604: 147-157. 10.1016/j.aca.2007.09.058.

    Article  CAS  Google Scholar 

  10. Baronti C, Curini R, D'Ascenzo G, di Corcia A, Gentili A, Amperi R: Monitoring natural and synthetic estrogens at activated sludge sewage treatment plants and in a receiving river water. Environ Sci Technol. 2000, 34: 5059-5066. 10.1021/es001359q.

    Article  CAS  Google Scholar 

  11. Fendinger NJ, Begley WM, McAvoy DC, Eckhoff WS: Determination of alkyl sulfate surfactants in natural waters. Environ Sci Technol. 1992, 26: 2493-2498. 10.1021/es00036a024.

    Article  CAS  Google Scholar 

  12. Labadie P, Budzinski H: Development of an analytical procedure for determination of selected estrogens and progestagens in water samples. Anal Bioanal Chem. 2005, 381: 1199-1205. 10.1007/s00216-005-3055-1.

    Article  CAS  Google Scholar 

  13. Vanderford BJ, Pearson RA, Rexing DJ, Snyder SA: Analysis of endocrine disruptors, pharmaceuticals, and personal care products in water using liquid chromatography/tandem mass spectrometry. Anal Chem. 2003, 75: 6265-6274. 10.1021/ac034210g.

    Article  CAS  Google Scholar 

  14. Viglino L, Aboulfadl K, Daneshvar Mahvelat A, Prévost M, Sauvé S: On-line solid phase extraction and liquid chromatography/tandem mass spectrometry to quantify pharmaceuticals, pesticides and some metabolites in wastewaters, drinking, and surface waters. J Environ Monit. 2007, 10: 482-489. 10.1039/b800861b.

    Article  Google Scholar 

  15. Viglino L, Aboulfadl K, Prévost M, Sauvé S: Analysis of natural and synthetic estrogenic endocrine disruptors in environmental waters using on-line preconcentration coupled to LC-APPI-MS/MS. Talanta. 2008, 76: 1088-1096. 10.1016/j.talanta.2008.05.008.

    Article  CAS  Google Scholar 

  16. Garcia-Ac A, Segura PA, Viglino L, Fürtos A, Gagnon C, Prévost M, Sauvé S: On-line solid-phase extraction-LC-MS/MS using large volume injections: validation for trace organic contaminants in surface and drinking water. J Chromatogr A. 2009, 1216: 8512-8527. 10.1016/j.chroma.2009.10.015.

    Article  Google Scholar 

  17. Schwartz RD, Williams AL, Hutchinson DB: Microbial production 4,4'-dihydroxybiphenyl: biphenylhydroxylation by fungi. Appl Environ Microbiol. 1980, 39: 702-708.

    CAS  Google Scholar 

  18. Andreozzi R, Raffaele M, Nicklas P: Pharmaceuticals in STP effluents and their solar photodegradation in aquatic environment. Chemosphere. 2003, 50: 1319-1330. 10.1016/S0045-6535(02)00769-5.

    Article  CAS  Google Scholar 

  19. Aguilar C, Ferrer I, Borrull F, Marcé RM, Barcelo D: Monitoring of pesticides in river water based on samples previously stored in polymeric cartridges followed by on line solid-phase extraction-liquid chromatography-diode array detection and confirmation by atmospheric pressure chemical ionization mass spectrometry. Anal Chim Acta. 1999, 386: 237-248. 10.1016/S0003-2670(99)00033-1.

    Article  CAS  Google Scholar 

  20. Comber DW: Abiotic persistence of atrazine and simazine in water. Pesticide Science. 1999, 55: 696-702. 10.1002/(SICI)1096-9063(199907)55:7<696::AID-PS11>3.0.CO;2-7.

    Article  CAS  Google Scholar 

  21. Lyytikäinen M, Kukkomen JVK, Lydy MJ: Analysis of pesticides in water and sediment under different storage conditions using gas chromatography. Arch Environ Contam Toxicol. 2003, 44: 437-444. 10.1007/s00244-002-2168-1.

    Article  Google Scholar 

  22. Cotruvo J, Gordon G, Bull R: Analytical Support Part II-Shane Snyder, The Rate of Bromate Decomposition in the Simulated Human Stomach and Associated Studies, Final Project Report. 2005, National Water Research Institute, [http://www.nwri-usa.org/pdfs/2005%20Bromate%20Decomposition%20Report.pdf]

    Google Scholar 

  23. Ying GG, Kookana RS, Ru YJ: Occurrence and fate of hormone steroids in the environment. Environ Internat. 2002, 28: 545-551. 10.1016/S0160-4120(02)00075-2.

    Article  CAS  Google Scholar 

  24. Kuster M, de Alda MJL, Barcelo D: Analysis and distribution of estrogens and progestogens in sewage sludge, soils and sediments. Tr Anal Chem. 2004, 23: 790-798. 10.1016/j.trac.2004.08.007.

    Article  CAS  Google Scholar 

  25. Avdeef A: Solubility of sparingly-soluble ionizable drugs. Advanced Drug Delivery Reviews. 2007, 59: 568-590. 10.1016/j.addr.2007.05.008.

    Article  CAS  Google Scholar 

  26. Muñoza I, Gómez-Ramosa MJ, Agüera A, Fernández-Alba AR, García-Reyes JF, Molina-Díaz A: Chemical evaluation of contaminants in wastewater effluents and the environmental risk of reusing effluents in agriculture. Tr Anal Chem. 2009, 28: 676-694. 10.1016/j.trac.2009.03.007.

    Article  Google Scholar 

Download references

Acknowledgements

This work was made possible through the financial support of the Natural Sciences and Engineering Research Council of Canada (NSERC), the NSERC Industrial Chair on Drinking Water at the École Polytechnique de Montréal and equipment grants from the Canadian Foundation for Innovation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sébastien Sauvé.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

CDP carried out some of the initial laboratory work and data analysis. KA completed the laboratory work, all of the MS analysis and data treatment and drafted the manuscript. MP and SS conceived the study, SS coordinated the study and edited the text. All authors have read and approved the final manuscript.

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.

Authors’ original file for figure 1

Authors’ original file for figure 2

Authors’ original file for figure 3

Rights and permissions

Open Access This is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License ( https://creativecommons.org/licenses/by-nc/2.0 ), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

Reprints and permissions

About this article

Cite this article

Aboulfadl, K., De Potter, C., Prévost, M. et al. Time-dependent integrity during storage of natural surface water samples for the trace analysis of pharmaceutical products, feminizing hormones and pesticides. Chemistry Central Journal 4, 10 (2010). https://doi.org/10.1186/1752-153X-4-10

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1752-153X-4-10

Keywords