Skip to main content

Table 2 The wavelength used with ICP-OES, instrumental detection limit (IDL), limit of detection (LOD), limit of quantification (LOQ), correlation coefficient, and calibration equations

From: Multielement analysis coupled with chemometrics modelling for geographical origin classification of teff [Eragrostis tef (Zuccagni) Trotter] grains from Amhara Region, Ethiopia

Metal

Wavelength

IDL (mg/L)

LOD (mg/L)

LOQ (mg/L)

Correlation coefficient

Calibration equation

Na

589.592

0.069

2.16

7.22

0.9988

I = 9245C-7006.1

Mg

285.213

0.002

0.55

1.83

0.9999

I = 1575000C-287546.9

Ca

317.933

0.010

2.92

9.75

0.9990

I = 641100C-632445.1

Mn

257.610

0.001

0.54

1.79

0.9990

I = 4813000C-858583

Fe

238.204

0.004

0.67

2.25

0.9996

I = 590900C-131479.4

Cr

267.716

0.007

0.44

1.48

0.9991

I = 640200C-92120

Co

228.616

0.007

0.31

1.03

0.9994

I = 209100C-20260.1

Ni

231.604

0.015

0.39

1.30

0.9994

I = 185200C-20700.7

Cu

327.393

0.009

0.25

0.82

0.9996

I = 822900C-66599.7

Zn

206.200

0.005

0.75

2.50

0.9980

I = 96750C-24088.4

Cd

228.802

0.030

0.15

0.51

0.9995

I = 353000C-14855.8

K

766.490

–

6.78

21.3-

0.9968

I = 4614C + 3950.7

  1. *I is emission intensity and C is concentration