Skip to main content

Table 2 Results of eco-scale analysis for the determination of MOL employing the proposed Ag–NPs method and the reported LC method

From: Earth-friendly-assessed silver-nanoparticles spectrophotometric method for rapid and sensitive analysis of Molnupiravir, an FDA-approved candidate for COVID-19: application on pharmaceutical formulation and dissolution test

Methods

Proposed Ag–NPs method

Reported LC method [10]

Parameters

 

 Reagents

 

  Methanol

12

  Acetonitrile

4

  Ammonium acetate

4

  AgNO3

0

  PVP

0

  NaOH

2

  Phosphate buffer

0

 Instruments

  Spectrophotometer/LC–MS/MS

 

  Energy

0

[≤ 0.1 kWh/sample]

2

[> 0.1 kWh/sample]

  Occupational hazard

0

0

  Waste

3

6

  Total penalty points

Σ 5

Σ 28

  Analytical eco-scale total scorea,b

95

72

Excellent green analysis

Acceptable green analysis

  1. If the score is > 50, it indicates acceptable green analysis
  2. If the score is < 50, it indicates inadequate green analysis
  3. aAnalytical eco-scale total score = 100–total penalty points
  4. bIf the score is > 75, it indicates excellent green analysis