Skip to main content

Table 4 System suitability tests of the proposed RP-HPLC method for the simultaneous determination of MTL, IND and BET

From: Application of Box-Behnken experimental design and response surface methodology for selecting the optimum RP-HPLC conditions for the simultaneous determination of methocarbamol, indomethacin and betamethasone in their pharmaceutical dosage form

Parameter

MTL

 

IND

 

BET

Reference value

Number of theoretical plates (N)

8821

 

8990

 

12,010

The higher the value, the more efficient the column is

Resolution factor (R)

 

8.54

 

7.52

 

> 2

Tailing factor (T)

0.76

 

0.72

 

0.88

≤ 2

Capacity factor (K´)

2.100

 

3.162

 

5.170

1–10

Selectivity factor (α)

 

1.45

 

1.35

 

≥ 1

% R.S.D. of tR of 6 injections

0.77

 

0.50

 

0.79

 
  1. Where tR: Retention time