Skip to main content

Table 1 Comparison of the published protocol for MP and PP parabens determination with proposed technique in the research

From: Chromium-based metal organic framework for pipette tip micro-solid phase extraction: an effective approach for determination of methyl and propyl parabens in wastewater and shampoo samples

Sample

Analyte(s)

Extraction method

Instrument

LOD (µg/L)

LOQ (µg/L)

Linear range (µg/L)

Refs.

Water, cosmetic creams, human urine

Methyl, ethyl, propyl, isopropyl, butyl and isobutyl and benzyl paraben

SPME

HPLC- UV

1.5–2.6

5.0–8.7

0.5–147.0

[1]

Human urine

Methyl, ethyl, propyl and butyl paraben

SPME

HPLC- UV

0.03–0.04 (µg/g)

0.40–0.97 (µg/g)

0.10–10.00 (µg/g)

[5]

River water, mouthwash, hand cream

Methyl, ethyl, propyl, isopropyl and butyl paraben

SPME

GC

0.0002–0.0500

Not mentioned

50.0–300.0

[6]

Wastewater and shampoo

Methyl and propyl paraben

PT-µSPE

Spectrophotometer

0.24–0.25

0.80–0.83

1.0–200.0

This work

  1. SPME solid phase microextraction, HPLC–UV high performance liquid chromatography–ultraviolet detection, GC gas chromatography