Skip to main content

Table 1 The matrix of actual and predicted values of particle size from CCRD experimental design

From: Modeling and optimization of nanoemulsion containing Sorafenib for cancer treatment by response surface methodology

Run no.

Overhead stirring time (min)

Shear rate (rpm)

Shear time (min)

Cycle of homogenizer (cycle)

Particle size (nm)

Actual

Predicted

1

160.00

3200.00

10.00

14.00

102.20

104.96

2

200.00

2000.00

25.00

11.00

105.20

102.73

3

200.00

4400.00

25.00

11.00

81.83

83.81

4

160.00

3200.00

20.00

14.00

77.96

76.26

5

160.00

3200.00

20.00

8.00

93.45

92.32

6

120.00

4400.00

25.00

17.00

92.67

94.23

7

160.00

3200.00

20.00

14.00

89.24

89.48

8

240.00

3200.00

20.00

14.00

85.87

86.07

9

200.00

4400.00

15.00

17.00

90.20

88.55

10

200.00

4400.00

15.00

11.00

81.20

84.60

11

200.00

2000.00

25.00

17.00

82.18

84.26

12

120.00

2000.00

15.00

17.00

75.31

74.99

13

200.00

4400.00

25.00

17.00

82.99

88.31

14

80.00

3200.00

20.00

14.00

91.94

88.50

15

160.00

3200.00

30.00

14.00

82.53

83.54

16

160.00

5600.00

20.00

14.00

77.55

78.42

17

160.00

3200.00

20.00

14.00

88.90

84.68

18

120.00

4400.00

15.00

17.00

75.28

77.32

19

120.00

2000.00

15.00

11.00

87.10

86.01

20

200.00

2000.00

15.00

11.00

88.36

87.27

21

120.00

4400.00

25.00

11.00

88.77

87.82

22

160.00

3200.00

20.00

14.00

89.23

88.00

23

200.00

2000.00

15.00

17.00

101.67

102.04

24

160.00

3200.00

20.00

20.00

89.91

87.36

25

120.00

4400.00

15.00

11.00

81.84

84.92

26

160.00

800.00

20.00

14.00

84.53

84.92

27

160.00

3200.00

20.00

14.00

85.90

84.92

28

120.00

2000.00

25.00

17.00

87.52

84.92

29

120.00

2000.00

25.00

11.00

82.15

84.92

30

160.00

3200.00

20.00

14.00

87.56

84.92