Skip to main content

Table 3 Results for metal ions determination in certified reference samples obtained using the optimum conditions.

From: Salicylic acid functionalized silica-coated magnetite nanoparticles for solid phase extraction and preconcentration of some heavy metal ions from various real samples

Samples

Certified value (μg g-1)

Found by proposed method (μg g-1)a

Calculated value of t-testb

Vehicle exhaust particulates (NIES-8)

Cd:1.1, Cr:3.3, Cu:67, Ni:18.5

Cd: 1.06 ± 0.04, Cr: 3.2 ± 0.2; Cu: 66.5 ± 0.4, Ni: 18.4 ± 0.3

1.96, 2.49, 2.54, 2.74

Human hair (NIES-5)

Cd: 5.2, Cu: 16.3, Ni: 1.8

Cd: 5.0 ± 4.0, Cu: 15.9 ± 2.8, Ni: 1.7 ± 4.8

2.23, 2.44, 2.00, 2.74

Tea leaves (NIES 7)

Cd: 0.030, Cr: 1.3, Cu: 7.0, Ni: 6.5

Cd: 0.028 ± 0.001, Cr: 1.2 ± 0.1, Cu: 6.7 ± 0.1, Ni 6.2 ± 0.1

1.70, 2.60, 2.22, 2.51

Pepperbush (NIES-1)

Ni: 8.7, Cd: 6.7

Ni: 8.8 ± 0.1, Cd: 6.6 ± 0.2,

1.34, 1.83

Zinc base diecasting alloy C (NBS-627)

Cu: 1320, Cd:51, Ni:29

Cu: 1310.2 ± 1.2, Cd: 49.1 ± 4.1, Ni: 27.5 ± 4.6

1.39, 2.11, 2.65

  1. (N = 5)
  2. a Mean of five determinations ± standard deviation
  3. b texp shows the experimental student-t values at confidence limit 95%.