Bimetallic MOF-based electrochemical sensor for determination of paracetamol in spiked human plasma

Abstract

Metal-organic frameworks (MOFs) with their exceptional properties have the potential to revolutionize the field of electrochemistry and pave the way for new and exciting applications. MOFs is an excellent choice as an active electrocatalyst component in the fabrication of electrochemical sensors. Here, bimetallic NiCo-MOFs, monometallic Ni-MOFs, and Co-MOFs were fabricated to modify the carbon paste electrode. Moreover, the ratio between Co and Ni within the bimetallic MOFs was optimized. Our aim in this work is to synthesize different compositions from bimetallic MOFs and systematically compare their catalytic activity with mono-metallic MOFs on paracetamol. The structure and properties of the 2D NiCo-MOFs were characterized by scanning electron microscope, X-ray photoelectron spectroscopy, Fourier transform infrared, and electrochemical method. Bimetallic Ni0.75Co0.25-MOFs modified carbon paste sensor displayed the optimum sensing performance for the electrochemical detection of paracetamol. A linear response over the range 6.00 × 10− 7 to 1.00 × 10− 4 M with a detection limit of 2.10 × 10− 8 M was obtained. The proposed method was applied to detect paracetamol in spiked human plasma and to determine paracetamol in the presence of its major toxic impurity, p-aminophenol. These findings suggest the considerable potential use of the newly developed sensor as a point-of-care tool for detecting paracetamol and p-aminophenol in the future.

Peer Review reports

Introduction

Electrochemical sensors are a remarkable class of sensors in which the electrode is the transducer element. These sensors (which appeared in the second half of the twentieth century) are now found in a wide range of commercial applications [1]. These sensors use the electrons to acquire signals, which is considered a clean model for analytical applications, with no generation of waste. In addition, they are miniaturized for use in portable devices, which allows for analyses with micro volumes of samples [1, 2]. Electrocatalysis is crucial for modern energy storage and conversion [3]. Advanced electrocatalysts help to decrease energy consumption in electrochemical processes [4]. Metal-organic frameworks (MOFs) which were reported in 1995 by Yaghi et al. [5], have shown great promise as electrocatalysts in recent years [4]. They represent a class of solid porous materials, which consist of metal nodes, and polydentate organic linkers [6]. They are considered a subset of coordination polymers and can be extended into one, two, and three dimensions [7]. MOFs have a wide diversity of skeleton and pores, network topology, surface functionalities, and charge mobility that result in tunable porosity [8]. They also introduce exciting new avenues for creativity in designing ligands, assembling crystal engineering [9], chemical separations, photocatalysis [10, 11], electrocatalysis [12], and energy storage materials candidates [7, 13]. Several strategies were developed to enhance the catalytic activity, such as element doping [14, 15], coordination structures optimization, and or defects construction [16,17,18]. Another strategy is the regulation of the number of accessible active sites of MOFs by different methods such as morphology engineering [19,20,21]. Unlike monometallic compounds, bimetallic MOFs provide numerous benefits for use as electrode components or as precursors in the production of advanced composites due to higher stability and efficiency [22]. Many experimental results proved that the inclusion of cobalt (Co) and nickel (Ni) transition elements creates more electrochemically active sites and increases catalytic activity [23, 24]. In 2016, Zhao et al. published a study of the electrocatalytic performance of NiCo bimetal-organic framework nanosheets on the oxygen evolution reaction [25].

Paracetamol (PAR), N-(4-hydroxyphenyl) acetamide (Fig. 1a) is commonly used as a painkiller and antipyretic. It is a suitable alternative for aspirin-sensitive patients [26]. PAR is usually used to relieve moderate pain, such as headaches caused by the flu, joint pain, and migraines [27]. The normal dose of PAR is not harmful to the human body [28]. However, PAR is a substrate of oxidative metabolism by Cytochrome P450 2E1 (CYP2E1), generating the toxic metabolite N-acetyl-p-benzoquinone imine (NAPQI). Overdosage of PAR can lead to hepatic necrosis through the diminution of cellular glutathione levels by forcing NAPQI to interact with nucleophilic cellular macromolecules [28]. The widespread availability and usage of PAR increase the incidence of accidental or intentional overdoses globally [29]. Each year, PAR overdoses result in approximately 56,000 emergency room visits, 33,000 hospitalizations, and 500 deaths [29].

Fig. 1
figure 1

Chemical structure of PAR and p-AP

Like many other drugs, PAR undergoes degradation during storage. The manufacturing process also introduces some impurities [30]. Para-aminophenol (p-AP), (Fig. 1b) is the primary PAR impurity. It is nephrotoxic and can cause teratogenicity [31].

Therefore, a simple, sensitive, and precise method of determining PAR in the presence of p-AP is significant for personal health care. Compared to traditional spectrophotometry [32]or chromatography [33], the electrochemistry technique is simple, has a fast response, high sensitivity, and low cost [34,35,36]. The detection of PAR by electrochemical sensors has attracted much interest in recent years. Various designs were detected including screen-printed electrodes [37], carbon-based electrodes [38], and nanomaterial-modified electrodes [39], to enhance sensitivity and selectivity towards PAR. The choice of electrode materials is critical for the sensor’s performance. Carbon-based materials such as graphene, carbon nanotubes, and carbon nanofibers have been widely investigated due to their high conductivity, large surface area, and electrocatalytic properties [40]. Surface functionalization techniques, such as electrodeposition, molecular imprinting [38], and electropolymerization [38], have been employed to enhance the selectivity of electrochemical sensors toward PAR. Electrochemical detection methods for PAR include voltammetric techniques, such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV), which are commonly used for their high sensitivity and ease of implementation in sensor devices [41]. Efforts have been made to miniaturize electrochemical sensors for PAR detection, to be integrated into portable devices for on-site analysis [42]. Several strategies have been developed to enhance the selectivity of electrochemical sensors for PAR detection by minimizing interference from other electroactive species found in real samples [42]. This includes the use of selective electrode materials, signal processing, and sample pretreatment techniques [43, 44].

In our presented study, novel functional nanomaterials have been developed to create modified electrodes for the sensitive and specific electrochemical detection of PAR in the presence of its primary impurity, p-AP. Bimetallic NiCo-metal-organic frameworks (NiCo-MOFs) were used to modify carbon paste electrodes (CPE), which were synthesized and subsequently compared for catalytic activity with monometallic Ni-MOFs/CPE and Co-MOFs/CPE using PAR as a representative drug model. Results revealed that NiCo-MOFs/CPE exhibited significant electrocatalytic performance in the redox process of PAR compared to both monometallic Ni-MOFs/CPE and Co-MOFs/CPE. Furthermore, the developed sensor was successfully employed for PAR detection in pharmaceutical formulations and spiked human plasma samples.

MOFs-modified sensors can maintain their sensing performance over extended periods due to their known structure stability and this ensures reliable and continuous monitoring of PAR levels without significant degradation. MOFs-modified sensors can be integrated into portable and miniaturized devices for on-site detection of PAR. This has implications in point-of-care diagnostics, where rapid and sensitive detection of paracetamol levels is crucial for patient care.

Experimental

Materials and reagents

Polyvinyl pyrrolidine K30 (PVP), purified terephthalic acid (PTA), nickel (II) sulfate hexahydrate, cobalt (II) chloride hexahydrate, dimethyl formamide (DMF), sodium hydroxide, graphite, phosphate-buffered saline (PBS) tablets, and p-aminophenol were purchased from Sigma-Aldrich. PAR was obtained from the Egyptian Drug Authority (EDA) (with a certified purity of 99.58% ± 1.01). Ethanol of HPLC grade was supplied from Fisher Scientific (Loughborough, Leicestershire, UK). Deionized water was prepared by double distillation (Agela Technologies Wilmington, USA). Blank human plasma was supplied from the Holding Company for Biological Products and Vaccines (VACSERA, Egypt).

Instrumentation

A PC-controlled electrochemical analytical workstation (Metrohm Autolab potentiostat/ galvanostat PGSTAT204) supplied with NOVA software for electrochemistry was applied for all voltammetric measurements. The used reference electrode was Ag/AgCl, while a Pt wire was utilized as a counter electrode. The working electrode used was CPE. For the analysis of spiked human plasma, the samples were mixed using a vortex (VELP Scientifica, Europe), and then centrifuged using a Centurion K241R centrifuge (UK). The solution’s pH was adjusted using Jenway digital ion analyzer model 3330 with Jenway pH glass electrode (Essex, UK). The SEM image of Ni0.75: Co0.25-MOFs was obtained using the ZEISS EVO scanning electron microscope in Hamburg, Germany. The structure of Ni0.75: Co0.25-MOFs was characterized through XPS, K-ALPHA (Thermo Fisher Scientific, USA) utilizing monochromatic X-ray Al K-alpha radiation − 10 to 1350 eV, spot size 400 μm, at specified pressure 10−9 mbar with full spectrum pass energy 200 eV and narrow spectrum at 50 eV. Fourier transform infrared spectrum (FT-IR) of the NiCo- MOFs was obtained by an FTS- 3000 spectrometer in the range from 4000 to 400 cm− 1.

Fabrication of MOFs

Fabrication of monometallic Ni-MOFs and Co-MOFs

A solvothermal method was used to prepare Ni-MOFs [12]. Thus, NiSO4.6H2O (0.144 g), PTA (0.25 gm), and PVP (0.5 gm) were poured in DMF (30 mL), then 3mL 0.4 M NaOH was added dropwise while stirring for 20.0 min. A faint green colloidal suspension was obtained and then subjected to a solvothermal reaction for 8 h at 100 °C inside a 50-mL Teflon autoclave. Next, the product was cooled down to room temperature, followed by centrifugation at 4000 rpm for 14.0 min to obtain the precipitate then washed with DMF and ethanol, and finally dried at 65 °C for 1 h under vacuum condition. Moreover, Co-MOFs was prepared by the same procedure using CoCl2.6H2O.

Fabrication of bimetallic Ni/Co-MOFs

Different molar ratios of Ni and Co were prepared (1:1), (3:1), and (1:3) then the same procedures were applied to prepare different bimetallic NiCo-MOFs as mentioned in.

Fabrication of MOFs modified carbon paste electrodes

The working modified electrodes were prepared as follows: 190.00 mg graphite was weighed and placed in mortar. Then 10.0 mg of synthesized Ni-MOFs, Co-MOFs, Ni0.25Co0.75−MOFs, Ni0.5Co0.5−MOFs, and Ni0.75Co0.25−MOFs mixed at least for 5.0 min using 0.50 mL paraffin oil. Each modified paste was filled in the electrode body and a copper wire was used for electrode connection. The CPE was prepared in the same procedure without MOFs mixing. The new surface of the paste electrode surface was simply renewed by scraping off about 3.0 mm of its old surface and polishing the new surface with a piece of tracing paper. Modified CPE sensors with varied MOFs composition can be recorded as Ni-MOFs/CPE, Co-MOFs/CPE, Ni0.25Co0.75-MOFs/CPE, Ni0.5Co0.5 -MOFs/CPE, and Ni0.75Co0.25 -MOFs/CPE.

Procedure

Standard solution

Stock standard solution of PAR was prepared by accurately weighing 0.38 g of pure drug and transferring it to a 100-mL volumetric flask then dissolved in 50-mL distilled water and completed to the mark with distilled water. Then one mL from the prepared solution was transferred into a 25-mL volumetric flask and completed to the mark with distilled water to obtain a PAR solution of concentration equal to 10–3M.

Operational conditions of electrochemical measurements

Cyclic wave voltammograms were obtained by scanning the potential over a range of -0.1 to 1.2 V, starting from 0. A carbon paste electrode (CPE) was used versus the reference electrode Ag/AgCl, with a platinum wire as a counter electrode. All determinations were carried out at room temperature. DPV measurements were conducted by scanning the potential over a range of -0.4 to 1.0 V at a scan rate of 40 mV/s. The sample width, modulation amplitude, pulse width (modulation time), pulse period (interval), and quiet time were set to 17.0 ms, 40.0 mV, 50.0 ms, 600.0 ms, and 5.0 s, respectively. These parameters were carefully chosen to ensure accurate and reliable measurements.

Construction of calibration curve

Aliquots of PAR were transferred from the stock solution to 25-ml volumetric flasks. The volumes were then accurately completed using PBS pH 7.4 to produce the desired final concentrations ranging from 0.60 µM to 100.00 µM. DPV was produced between -0.4 and 1.0 V. The current peak height confidently recorded for each sample was plotted against its corresponding concentration to determine the calibration curve and regression equation.

Method validation

The developed method was successfully validated following ICH guidelines [45] for linearity, accuracy, precision, detection, and quantification limits, confirming its suitability for the intended use. Linearity was thoroughly investigated under optimal electrochemical conditions by analyzing six different concentrations of PAR. Accuracy was rigorously assessed by calculating the percentage recovery of three different concentrations. Intra-day and inter-day precision were evaluated and reported as %RSD.

Application procedure

Analysis of PAR in real samples

For the preparation of the real sample of PAR tablet (labelled 500 mg), ten PAR tablets were crushed. Then, 5.09 mg of this powder was dissolved in 25.00 mL of deionized water under ultra-sonication to prepare a concentration of 10− 3 M. The resulting sample was filtered using filter paper to remove impurities and fillers in the tablet.

A specific volume of this solution was transferred to a volumetric flask (25 mL) and diluted with PBS (pH = 7.4). Finally, the obtained concentrations were analyzed to calculate the recovery percentage.

Analysis of PAR in spiked human plasma

A standard stock solution of 1.00 mM PAR was prepared by dissolving 3.80 mg of pure PAR powder in 25.00 mL of distilled water. From this solution, various working standard solutions were prepared. Then, 500.00 µL was withdrawn from each working solution and added separately to 500.00 µL of plasma in a 10-mL centrifuge tube. Protein precipitation was efficiently achieved by adding 1.50 mL of acetonitrile. The mixtures were blended using a vortex mixer for 5.0 min at 4000 rpm, followed by a carefully timed centrifugation for 15.0 min at 4000 rpm. The supernatant was transferred and evaporated to complete dryness utilizing the rotatory vacuum concentrator at 60. Samples were reconstituted in 25.00 mL of PBS to obtain the final desired concentrations of 1.00 × 10–5, 4.00 × 10–5, 6.00 × 10–5, 8.00 × 10–5, and 1.00 × 10–4 M. DPV was generated for those spiked samples in the range from -0.4 to 1.0 V. To construct a calibration curve, the current peak heights of the measured concentrations were used and correlated with their corresponding concentrations. To evaluate the accuracy, the percentage recovery of three different concentrations was calculated.

Results and discussion

Compared to traditional porous materials, the most attractive advantage of MOFs is that their catalytic activity can be enhanced using different metal ions and organic linkers. Purified terephthalic acid (PTA) was used as a ligand. Nickel sulfate and cobalt chloride were used as ion sources to synthesize 2D MOFs through a solvothermal method [12]. PVP was assembled as a polymer in the fabrication of MOFs to prevent aggregation and provide a larger surface area and more active sites to interact with the PAR. To investigate the redox property of the CPE sensor modified with the porous NiCo-MOFs, a DPV study was conducted on plain CPE and NiCo-MOFs/CPE sensors as shown in Fig. 2. The NiCo-MOFs/CPE sensor exhibited better-defined oxidation and reduction properties of the ferro/ferri cyanide solution than the plain CPE sensor. The synthesized bimetallic NiCo-MOFs have more catalytic activity than monometallic Ni-MOFs and Co-MOFs, Fig.  3 and Figure S1. The catalytic performance of different molar ratios of Ni and Co were examined (Ni0.25Co0.75, Ni0.5Co0.5, Ni0.75Co0.25) and compared, results are shown in Fig. 3. The molar ratio of Ni0.75Co0.25-MOFs was revealed to have the most catalytic activity, Fig. 3. Then several percentages of the optimized molar ratio Ni0.75Co0.25-MOFs (1%, 2%, 5%, and 10%) were carried out. The best results were achieved by applying 5% Ni0.75Co0.25-MOFs to CPE where a high current was obtained, Fig.  4.

Fig. 2
figure 2

Differential pulse voltammograms of PAR using potassium ferro/ferricyanide solution (0.01 mM) in PBS buffer at solid CPE with/without NiCo-MOFs

Fig. 3
figure 3

Differential pulse voltammograms of PAR on the Ni-MOFs/CPE, Co-MOFs/CPE, Ni0.25Co0.75-MOFs/CPE, Ni0.5Co0.5-MOFs/CPE, and Ni0.75Co0.25-MOFs/CPE using scan rate 40 mV/s and pH 7.4

Fig. 4
figure 4

Differential pulse voltammograms of PAR on different percentages of Ni0.75Co0.25-MOFs (1%, 2%, 5%,10%) using scan rate 40 mV/s and pH 7.4

Surface characterization of bimetallic Ni0.75Co0.25-MOFs/CPE

The morphology of the synthesized NiCo-MOFs was examined using SEM. A cauliflower-shaped structure aggregates were obtained with average length of 5.4 ± 1.3 μm and width of 3.1 ± 0.74 μm of the cluster Fig.  5. Moreover, energy dispersion X-ray (EDX) analysis was used for the elemental analysis. The elemental mapping of NiCo-MOFs confirmed the presence of Ni, Co, C, and O in the structure Fig. 6. This was also confirmed by the XPS technique that was used to analyze the elemental structure of NiCo-MOFs. The survey spectrum clearly showed the presence of Ni, Co, O, N, and C elements. The high-resolution XPS spectra were obtained. The Co(2p) high-resolution XPS spectrum shows three peaks at 780.4, 785.3, and 797.0 eV corresponding to Co2+ oxidation state. Similarly, Ni(2p) high-resolution XPS spectrum showed peaks at 855.6, 861.1, and 873.6 eV that could be assigned to Ni2+ oxidation state. Such results showed electronic interactions between Co and Ni atoms found in Ni0.75Co0.25-MOFs which would improve the electro-catalytic properties of MOFs. The C(1s) spectra showed peaks at around 283.9, 284.1, and 287.6 eV corresponding to C = C, C = O, and O-C = O. The N(1s) spectra had two major peaks at 399.58 eV for pyridinic-N and 401.1 eV for pyrrolic-N indicating the formation of MOFs on the PVP polymer. From the infrared spectrum of Ni0.75Co0.25−MOFs (Figure. S2), it can be observed that a new characteristic absorption peak appears at 1377 cm− 1 and 1577 cm− 1 which corresponded to asymmetric and symmetric stretching modes of coordinated carboxylic acid, respectively [46]while the broad peaks in the spectral range of 3150–3400 cm− 1 may be due to acidic OH of carboxylic groups [47]. The peaks at 1161 and 1099 m− 1 are attributed to the in-plane stretching vibration of C-H while the peaks at 756 and 813 cm− 1 are assigned to the out-of-plane bending vibration of C-H [48]. The absorptions around 466, 524, 559, and 609 cm− 1 are related to metal–oxygen–hydrogen bending vibration (Ni-O or Co-O or Ni-Co-O bond) [47].

Fig. 5
figure 5

SEM image of cauliflower-like Ni0.75Co0.25-MOFs

Fig. 6
figure 6

EDX spectrum of Ni0.75 Co0.25-MOFs

Electrochemical characterization

Electrochemical Impedance Spectroscopy (EIS) of different electrodes was often performed using [Fe (CN)6]−3/ [Fe (CN)6]−4 redox probes [49,50,51]. As shown in Figure S3, the different sizes of the semicircle for each curve, it can be concluded that the Charge transfer resistance (Rct) of Ni 0.75Co0.25-MOFs/CPE was significantly lower than that of CPE. The Rct of CPE and Ni 0.75Co0.25-MOFs/CPE were 1.15, 0.788 kΩ. This suggests that Ni 0.75Co0.25-MOFs was successfully coated on the electrode surface, and the introduction of conductive Ni 0.75Co0.25-MOFs was a reliable way to reduce the Rct of CPE and thus promote electron transfer.

Electrochemical performance of PAR on the Ni0.75Co0.25-MOFs/CPE surface

The effect of buffer and pH

To obtain better electrochemical sensing performance, the detection conditions were optimized using CV. Firstly, three types of buffers were tried: acetate, Britton -Robinson Buffer (BRB), and PBS each at pH 7.0. The peak potential of PAR was maximum with the PBS buffer. Then, the pH ranges between 5.0 and 7.0 through PBS buffer were studied to determine the impact of the pH value of the electrolyte on the response of PAR. Because the pKa value is 9.5 for PAR, therefore it carries a positive charge at pH values lower than their pKa values [52]. As shown in Fig. 7, the oxidation peak current of PAR increased as pH values increased from 5.0 to 7.0 as at lower pH, PAR is more protonated, meaning it has gained a hydrogen ion (H+) and exists in a charged form. This may hinder its oxidation process, resulting in lower peak currents. As the pH increases to pH 7.0 (Neutral), PAR becomes less protonated and more in its neutral form. This neutral form enhanced electrochemical activity, leading to higher oxidation peak currents [53]. For achieving higher sensitivity, pH 7.4 was selected as an optimal pH to electrochemically detect PAR on the Ni0.75Co0.25-MOFs/CPE.

Fig. 7
figure 7

Effect of pH on the cathodic peak current (Ip)

The effect of scanning rate

The impact of the scanning rate was studied on the anodic oxidation peak of PAR using CV. The CV curves of 0.1mM PAR on the Ni0.75Co0.25-MOFs/CPE were plotted in Fig. 8, with scanning rates ranging from 10.0 to 100.0 mV/s. Figure 9 demonstrates a clear linear relationship between the logarithm of peak current (IP) and the logarithm of scan rate (ʋ), the equation of regression log IP = 0.6995 log ʋ − 6.3203 (r = 0.9976), showed that the slope is higher than the theoretical value of 0.50. This indicates that the anodic reaction at the electrode surface is a process controlled by diffusion, with some adsorption character. This regression equation IP=1.4038 ʋ1/2 − 2.3087 (r = 0.9948), demonstrated that there is a direct proportionality between, the peak current (IP) and the square root of the scan rate (ʋ1/2) within the range of scan rate from 10.0 to 100.0 mV/s, as shown in Fig. 10.

Fig. 8
figure 8

Cyclic Voltammograms of 0.1mM PAR in 10 mM PBS (pH 7.4) on the Ni0.75Co0.25-MOFs /CPE at different scanning rates: 10, 20, 40, 60, 80, and 100 mV/s

Fig. 9
figure 9

A plot of logarithm of anodic peak current (log Ip) of PAR as a function of the logarithm of scan rate (log ʋ) using cyclic voltammetry

Fig. 10
figure 10

A plot of the anodic peak current (Ip) of PAR as a function of the square root of scan rate (ʋ1/2)

Moreover, as shown in Figure S4, during our study, the long-term stability of the developed sensor was assessed. The electrode was stored in the presence of air and measured every five days for two months to record the data regarding the change in the peak current values. The results show a loss of only 10.42% in the current value. Although bimetallic MOFs showed enhanced characteristics in terms of catalytic activity, they have a limitation of being commonly aggregated and difficulty controlling the pore structure. They lack the backbone to guard against structure deformation or aggregation. That shall direct our plans in future work to a template-assisted synthesis and controlled fabrication of “quasi-MOFs” [54].

Suggested mechanism of PAR electrochemical oxidation

The number of electrons involved in the reaction for an irreversible electrochemical process is calculated using the Laviron Eqs. [55, 56]

$$E=E \circ+2.303 R T / \alpha n F,[\log R \text { at } \mathrm{K} \circ / \alpha n F]+2.303 R T / \alpha n F(\log v)$$

All symbols have their standard meaning. For the system under study, using slope (0.0556), generated from linear plot of potential against log scan rate αn was calculated to be 1.032 for PAR at Ni0.75Co0.25-MOFs/CPE. Since an irreversible electron transfer α assumed to be 0.5 [56], therefore “n” value was calculated to be 2.064 PAR, which is consistent with 2 electron transfer processes involved in the oxidation of PAR at the modified electrode. Scheme 1 illustrates the possible electrochemical oxidation mechanism of PAR.

Scheme 1
figure 1

Electrochemical oxidation mechanism of PAR

Analytical performance of PAR

Calibration curve and detection limit

The DPV method was used to measure the PAR peak current and was found to be linear within the range of 0.60–100.00 µM under the optimum electrochemical conditions as presented in Fig. 11, and Fig. 12 with the sensitivity of 0.0564 µA µΜ−1 cm− 2 and a low detection limit of 0.02 µM as mentioned in Table 1. A comparison between the detection limits/analytical range reported for PAR on various electrode systems [57,58,59,60,61] and that observed in the present work has been performed as shown in Table 2.

Fig. 11
figure 11

DPVs of different concentrations of PAR on the Ni0.75Co0.25-MOFs/CPE in 0.1 M PBS (pH = 7.4)

Fig. 12
figure 12

The peak current plot as a function of the concentration of PAR

Table 1 Validation parameters obtained by the developed DPV method for determination of PAR in the presence of p-AP
Table 2 A comparison of analytical performance for PAR in electrodes modified with different materials

Method validation

By examining three different concentration levels of PAR and calculating the percentage recovery, the suggested method was found to be accurate. The suggested method was precise based on the assessment of intra-day and inter-day precision, with % RSD values within the accepted range of less than 2%. The results of LOD, accuracy, and precision are shown in Table 1. As shown in Fig. 13, the method studied was also considered specific for its ability to efficiently detect PAR with uniform peak without interfering with its main impurity p-AP.

Fig. 13
figure 13

Differential pulse voltammograms of PAR and p-AP on the Ni0.75Co0.25-MOFs/CPE in 10 mM PBS (pH 7.4)

Analytical applications

Analysis of PAR in the real samples

As our research was aimed at evaluating a new approach in practice, Ni0.75Co0.25-MOFs/CPE was used for PAR detection in its commercial tablet. As seen in Table 3, the recovery of PAR is from 98.77 to 99.81%, indicating the possible use of our electrochemical sensor to detect PAR in actual samples.

Table 3 Results of PAR analysis in real samples form by the developed DPV method

Analysis of PAR in spiked human plasma

Tables 4 and 5 summarize the results of the accuracy and precision of the analysis of spiked human plasma samples by the suggested method. Our developed method was able to detect concentrations as low as 10− 5M, which is lower than the previously reported Cmax value [62]. This confirms that our method is suitable for analyzing PAR in real human plasma samples.

Table 4 Analysis results of plasma samples spiked with different concentrations of PAR
Table 5 Results of the proposed DPV method accuracy in spiked human plasma samples

Statistical data analysis

The results obtained by Ni0.75Co0.25-MOFs/CPE were compared with those obtained by applying the official method for the determination of the PAR pure sample [27]. The t-test and F-value [63]were used to compare the mean and variance between the two methods where no significant difference in the results was found (Table 6).

Table 6 Statistical comparison of the results obtained by the proposed and official methods for the analysis of PAR in its pure form

The schematic representation of the electrochemical platform of MOFs synthesis and voltammetric measurements of PAR is summarized in Fig. 14.

Fig. 14
figure 14

Schematic representation of monometallic and bimetallic MOFs synthesis and voltammetric measurements of PAR

Conclusion

Bimetallic NiCo-MOFs with complex composition and structure show superior catalytic activity compared to their monometallic counterparts Ni-MOFs and Co-MOFs. An electrochemical sensing platform based on 2D Ni0.75Co0.25-MOFs/ CPE was successfully fabricated and employed in the detection of PAR in the presence of p-AP with a peak potential separation of 280.0 mV. Good electrochemical performance was attributed to the porous structure of MOFs, the good electrocatalytic activity, and the synergetic effect of Ni and Co. The constructed electrochemical sensor showed good selectivity and high sensitivity for PAR under optimized experimental conditions. The developed Ni0.75Co0.25-MOFs/CPE had a broad linearity range (0.60–100.00 µM) and a low limit of detection of 0.02 µM, this allows its use for pharmacokinetic studies in the future. In addition, the analysis of real samples and human plasma samples revealed the successful applicability of the developed sensor as a point of care in determining PAR. This work also provided a simple and general strategy for constructing MOFs-based electrochemical sensors.

Data availability

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

References

  1. Simões FR, Xavier MG. 6 - Electrochemical sensors. In: Da Róz AL, Ferreira M, de Lima Leite F, Oliveira ON, editors. Nanoscience and its applications. William Andrew Publishing; 2017. pp. 155–78.

  2. El-Hadi HRA, Eissa MS, Eltanany BM, Zaazaa HE, Arafa RM. Greenness and whiteness assessment of a sustainable voltammetric method for difluprednate estimation in the presence of its alkaline degradation product. Sci Rep. 2024;14:12088.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Shah R, Ali S, Raziq F, Ali S, Ismail PM, Shah S et al. Exploration of metal organic frameworks and covalent organic frameworks for energy-related applications. Coord Chem Rev. 2023;477.

  4. Li Z, Song M, Zhu W, Zhuang W, Du X, Tian L. MOF-derived hollow heterostructures for advanced electrocatalysis. Coord Chem Rev. 2021;439.

  5. Yaghi OM, Li G, Li H. Selective binding and removal of guests in a microporous metal–organic framework. Nature. 1995;378:703–6.

    Article  CAS  Google Scholar 

  6. Alzahrani FM, Alsaiari NS, Katubi KM, Amari A, Tahoon MA. Synthesis, characterization, and application of magnetized Lanthanum (III)-Based Metal-Organic Framework for the Organic dye removal from Water. Adsorpt Sci Technol. 2022.

  7. Dutt S, Kumar A, Singh S. Synthesis of Metal Organic frameworks (MOFs) and their derived materials for Energy Storage Applications. Clean Technol. 2023;5:140–66.

    Article  Google Scholar 

  8. Beitollahi H, Van Le Q, Farha OK, Shokouhimehr M, Tajik S, Nejad FG, et al. Recent electrochemical applications of metal-organic framework-based materials. Cryst Growth Des. 2020;20:7034–64.

    Article  Google Scholar 

  9. Xie LS, Skorupskii G, Dincǎ M. Electrically Conductive Metal-Organic frameworks. Chem Rev. 2020;120:8536–80.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  10. Laurier KGM, Vermoortele F, Ameloot R, De Vos DE, Hofkens J, Roeffaers MBJ. Iron (III)-based metal-organic frameworks as visible light photocatalysts. J Am Chem Soc. 2013;135:14488–91.

    Article  CAS  PubMed  Google Scholar 

  11. Fateeva A, Chater PA, Ireland CP, Tahir AA, Khimyak YZ, Wiper PV, et al. A water-stable porphyrin-based metal-organic framework active for visible-light photocatalysis. Angewandte Chemie - Int Ed. 2012;51:7440–4.

    Article  CAS  Google Scholar 

  12. Raptopoulou CP. Metal-organic frameworks: synthetic methods and potential applications. Materials. 2021;14:1–32.

    Article  Google Scholar 

  13. Deng T, Zhang W, Arcelus O, Wang D, Shi X, Zhang X et al. Vertically co-oriented two-dimensional metal-organic frameworks for packaging enhanced supercapacitive performance. Commun Chem. 2018;1.

  14. Wu Y, Tian J, Liu S, Li B, Zhao J, Ma L, et al. Bi-microporous Metal-Organic frameworks with cubane [M4(OH)4 ] (M = Ni, Co) clusters and pore‐space partition for electrocatalytic methanol oxidation reaction. Angew Chem. 2019;131:12313–7.

    Article  Google Scholar 

  15. Xue Z, Li Y, Zhang Y, Geng W, Jia B, Tang J et al. Modulating electronic structure of Metal-Organic Framework for efficient Electrocatalytic Oxygen Evolution. Adv Energy Mater. 2018;8.

  16. Shan Y, Zhang G, Shi Y, Pang H. Synthesis and catalytic application of defective MOF materials. Cell Rep Phys Sci. 2023;4.

  17. Heidary N, Chartrand D, Guiet A, Kornienko N. Rational incorporation of defects within metal-organic frameworks generates highly active electrocatalytic sites. Chem Sci. 2021;12:7324–33.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  18. Khalil IE, Xue C, Liu W, Li X, Shen Y, Li S et al. The role of defects in Metal-Organic frameworks for Nitrogen Reduction reaction: when defects switch to features. Adv Funct Mater. 2021;31.

  19. Bai Y, Liu C, Shan Y, Chen T, Zhao Y, Yu C et al. Metal-Organic frameworks nanocomposites with different dimensionalities for Energy Conversion and Storage. Adv Energy Mater. 2022;12.

  20. Hai G, Jia X, Zhang K, Liu X, Wu Z, Wang G. High-performance oxygen evolution catalyst using two-dimensional ultrathin metal-organic frameworks nanosheets. Nano Energy. 2018;44:345–52.

    Article  CAS  Google Scholar 

  21. Chao S, Xia Q, Wang Y, Li W, Chen W, Pristine S. N-containing Mn-based metal organic framework nanorods enable efficient oxygen reduction electrocatalysis. Dalton Trans. 2020;49:4336–42.

    Article  CAS  PubMed  Google Scholar 

  22. Zhou Y, Abazari R, Chen J, Tahir M, Kumar A, Ikreedeegh RR et al. Bimetallic metal–organic frameworks and MOF-derived composites: recent progress on electro- and photoelectrocatalytic applications. Coord Chem Rev. 2022;451.

  23. Li H, Qian X, Xu C, Huang S, Zhu C, Jiang X, et al. Hierarchical porous Co9S8/Nitrogen-Doped Carbon@MoS2 polyhedrons as pH Universal Electrocatalysts for highly efficient hydrogen evolution reaction. ACS Appl Mater Interfaces. 2017;9:28394–405.

    Article  CAS  PubMed  Google Scholar 

  24. Dong Y, Zhou M, Zhang L. 3D multiporous Co, N co-doped MoO2/MoC nanorods hybrids as improved electrode materials for highly sensitive simultaneous determination of acetaminophen and 4-aminophenol. Electrochim Acta. 2019;302:56–64.

    Article  CAS  Google Scholar 

  25. Zhao S, Wang Y, Dong J, He CT, Yin H, An P et al. Ultrathin metal-organic framework nanosheets for electrocatalytic oxygen evolution. Nat Energy. 2016;1.

  26. Sweetman SC. Martindale: the complete drug reference. 36th edition. London: Pharmaceutical Press; 2009.

  27. The British Pharmacopoeia. The Stationary Office, London; 2016.

  28. Brunton LL, Hilal-Dandan R, Knollmann BC. The pharmacological basis of Therapeutics. 13th edition. 2017.

  29. Zhang Y, Huang Z, Wang L, Wang C, Zhang C, Wiese T, et al. Point-of-care determination of Acetaminophen levels with Multi-hydrogen Bond manipulated single-molecule recognition (eMuHSiR). Anal Chem. 2018;90:4733–40.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  30. Braimah HY, Tijjani AB, Amos SC. Impurity profiling of paracetamol dosage forms used IN Maiduguri Metropolis. World J Pharm Res. 2019;8:1659–85.

    CAS  Google Scholar 

  31. El Sherbiny D, Wahba MEK. Analysis of some pharmaceuticals in the presence of their synthetic impurities by applying hybrid micelle liquid chromatography. Open Chem. 2020;18:377–90.

    Article  Google Scholar 

  32. Tan C, Gao N, Zhou S, Xiao Y, Zhuang Z. Kinetic study of acetaminophen degradation by UV-based advanced oxidation processes. Chem Eng J. 2014;253:229–36.

    Article  CAS  Google Scholar 

  33. Youssef SH, Mohamed D, Hegazy MAM, Badawey A. Analytical methods for the determination of Paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets. BMC Chem. 2019;13.

  34. Bakker E. Ion-selective electrodes: Liquid membrane. Encylopedia of Analytical sciences-Second Edition. Elsevier; 2005. pp. 509–14.

  35. Nahorniak M, Pasetto P, Greneche JM, Samaryk V, Auguste S, Rousseau A, et al. Two-step single-reactor synthesis of oleic acid- or undecylenic acid-stabilized magnetic nanoparticles by thermal decomposition. Beilstein J Nanotechnol. 2023;14:11–22.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  36. Adeyemi Oladipo A. Cu0-doped graphitic carbon quantum dots for rapid electrochemical sensing of glyphosate herbicide in environmental samples. Microchem J. 2024;200.

  37. Bahar SL, Permatasari LM, Madurani KA, Kurniawan F. Determination of Paracetamol using screen-printed carbon electrode. Int J Health Sci. 2022;1968–77.

  38. Peng Y, Wu Z, Liu Z. An electrochemical sensor for Paracetamol based on an electropolymerized molecularly imprinted o-phenylenediamine film on a multi-walled carbon nanotube modified glassy carbon electrode. Anal Methods. 2014;6:5673–81.

    Article  CAS  Google Scholar 

  39. Atta NF, Galal A, Azab SM. Electrochemical Determination of Paracetamol Using Gold Nanoparticles-Application in tablets and human fluids. Int J Electrochem Sci. 2011.

  40. Kang X, Wang J, Wu H-X, Liu W, Aksay I, Lin Y. A graphene-based electrochemical sensor for sensitive detection of Paracetamol. Talanta. 2010;81:754–9.

    Article  CAS  PubMed  Google Scholar 

  41. Rezaei B, Irannejad N. Electrochemical detection techniques in biosensor applications. Electrochemical biosensors. Amsterdam: Elsevier; 2019. pp. 11–43.

    Chapter  Google Scholar 

  42. Beitollahi H, Mohammadi S, Safaei M, Tajik S. Applications of electrochemical sensors and biosensors based on modified screen printed electrodes: a review. Anal Methods. 2020;12.

  43. Han T, Mattinen U, Bobacka J. Improving the sensitivity of solid-contact ion-selective electrodes by using Coulometric Signal Transduction. ACS Sens. 2019;4:900–6.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  44. Shao Y, Ying Y, Ping J. Recent advances in solid-contact ion-selective electrodes: functional materials, transduction mechanisms, and development trends. Chem Soc Rev. 2020;49.

  45. ICH Guideline Validation of analytical procedures: text and methodology, Q2 (R1. ), International Conference of Harmonization (ICH) of Technical Requirements for Registration of Pharmaceuticals for Human Use. Geneva, Switzerland; 2005.

  46. Salama RS, Abd El-Hakam S, Elsayed Samra S, El-Dafrawy SM, El-Hakam SA, Samra SE, et al. Adsorption, Equilibrium and kinetic studies on the removal of methyl orange dye from aqueous solution by the use of copper metal organic framework (Cu-BDC) Adsorption, Equilibrium and Kinetic studies on the removal of Methyl Orange Dye from Aqueous Solution by using of Copper Metal Organic Framework (Cu-BDC). Int J Mod Chem. 2018;10:195–207.

    CAS  Google Scholar 

  47. Radhika MG, Gopalakrishna B, Chaitra K, Bhatta LKG, Venkatesh K, Sudha Kamath MK et al. Electrochemical studies on Ni, Co & Ni/Co-MOFs for high-performance hybrid supercapacitors. Mater Res Express. 2020;7.

  48. Wang Y, Wu Y, Xie J, Hu X. Metal-organic framework modified carbon paste electrode for lead sensor. Sens Actuators B Chem. 2013;177:1161–6.

    Article  CAS  Google Scholar 

  49. Mouhamed AA, Eltanany BM, Mostafa NM, Elwaie TA, Nadim AH. Design of screen-printed potentiometric platform for sensitive determination of mirabegron in spiked human plasma; molecular docking and transducer optimization. RSC Adv. 2023;13:23138–46.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  50. Chen JY, Weng YX, Han YH, Ye RH, Huang DH. A novel pencil graphite electrode modified with an iron-based conductive metal-organic framework exhibited good ability in simultaneous sensing bisphenol A and bisphenol S. Ecotoxicol Environ Saf. 2024;272.

  51. Ye RH, Chen JY, Huang DH, Wang YJ, Chen S. Electrochemical Sensor based on glassy-Carbon Electrode modified with dual-ligand EC-MOFs supported on rGO for BPA. Biosensors.2022;12(367).

  52. Prescott L. Kinetics and metabolism of Paracetamol and phenacetin. Br J Clin Pharmacol. 1980;10 2:291–8.

    Google Scholar 

  53. Awad MI, Sayqal A, Pashameah RA, Hameed AM, Morad M, Alessa H, et al. Enhanced paracetamol oxidation and its determination using electrochemically activated glassy Carbon Electrode. Int J Electrochem Sci. 2021;16:1–15.

    Article  Google Scholar 

  54. Laviron E. The Use of Linear potential sweep voltammetry and of A.C. Voltammetry for the study of the Surface Electrochemical reaction of strongly Adsorbed systems and of Redox Modified electrodes. J Electroanal Chem. 1979;100:263–70.

    Article  CAS  Google Scholar 

  55. Atty SA, Ghany MFA, Hussein LAA, Magdy N, Yamani HZ. TiO2 nanoparticles and ionic liquid platform for selective electrochemical determination of indacaterol in pharmaceutical formulations and human fluids: application to content uniformity. J Iran Chem Soc. 2019;17:383–95.

    Article  Google Scholar 

  56. Chen L, Wang HF, Li C, Xu Q. Bimetallic metal-organic frameworks and their derivatives. Chem Sci. 2020;11:5369–403.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  57. Wu M, Wang L, Xu F, Ma G. Preparation of Ni-MOF superstructure-reduced graphene oxide composite for enhanced electrochemical sensing of acetaminophen. Ionics. 2022;28:5571–80.

    Article  CAS  Google Scholar 

  58. Dourandish Z, Sheikhshoaie I, Maghsoudi S. Molybdenum Disulfide/Nickel-Metal Organic Framework Hybrid Nanosheets Based Disposable Electrochemical Sensor for determination of 4-Aminophenol in Presence of Acetaminophen. Biosensors. 2023;13.

  59. Wang J, Liu S, Luo J, Hou S, Song H, Niu Y et al. Conductive Metal-Organic frameworks for Amperometric Sensing of Paracetamol. Front Chem. 2020;8.

  60. Sofi FA, Bhat MA, Majid K. Cu2+-BTC based metal-organic framework: a redox accessible and redox stable MOF for selective and sensitive electrochemical sensing of acetaminophen and dopamine. New J Chem. 2019;43:3119–27.

    Article  CAS  Google Scholar 

  61. Wang X, Wang Q, Wang Q, Gao F, Gao F, Yang Y, et al. Highly dispersible and stable copper Terephthalate Metal-Organic Framework–Graphene Oxide Nanocomposite for an Electrochemical sensing application. ACS Appl Mater Interfaces. 2014;6:11573–80.

    Article  CAS  PubMed  Google Scholar 

  62. Raffa RB, Pawasauskas J, Pergolizzi JV, Lu L, Chen Y, Wu S, et al. Pharmacokinetics of oral and intravenous paracetamol (Acetaminophen) when co-administered with intravenous morphine in healthy adult subjects. Clin Drug Investig. 2018;38:259–68.

    Article  CAS  PubMed  Google Scholar 

  63. Hassan AM, Kelani KM, Hegazy MA, Nadim AH, Tantawy MA. A probe of new molecularly imprinted solid-phase extraction coupled with HPLC-DAD and atomic absorption spectrophotometry for quantification of tetracycline HCl, metronidazole and bismuth subcitrate in combination with their official impurities: application in dosage form and human plasma. J Chromatogr B Analyt Technol Biomed Life Sci. 2024;1234.

Download references

Acknowledgements

Not applicable.

Funding

No funding was received for this study.

Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).

Author information

Authors and Affiliations

Authors

Contributions

A. A. M. Data curation, Software, Validation, and Writing- Original draft preparation. A. H. N. Software, Investigation, Writing- Reviewing and Editing. (A) M.M. Conceptualization, Methodology, Software, Reviewing, Editing.N. M.M. Conceptualization, Writing- Reviewing and Editing. (B) M. E. Investigation, Writing- Reviewing and Editing. All authors reviewed the manuscript.

Corresponding author

Correspondence to Aya A. Mouhamed.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary Material 1

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mouhamed, A.A., Nadim, A.H., Mahmoud, A.M. et al. Bimetallic MOF-based electrochemical sensor for determination of paracetamol in spiked human plasma. BMC Chemistry 18, 148 (2024). https://doi.org/10.1186/s13065-024-01247-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13065-024-01247-7

Keywords