Skip to main content

Table 1 Assay validation sheet of the proposed methods for the determination of pure samples of modafinil

From: Smart stability indicating spectrophotometric methods for determination of modafinil: the promising treatment for post-covid neurological syndrome

Parameter

RD

1DD

MCR

RS

Accuracy (mean ± SD)

99.97 ± 0.305

100.10 ± 0.560

100.02 ± 0.483

99.18 ± 0.1.145

Precision (RSD %)

Repeatability*

0.764

1.104

1.008

0.939

Intermediate precision**

0.855

0.958

0.952

1.112

Linearity

Slope

0.0362

0.1525

0.1812

0.0032

Intercept

0.1292

0.2614

0.235

0.0002

Correlation coefficient (r)

0.9999

0.9999

0.9999

0.9998

Range

(5-30 µg/mL)

(5-30 µg/mL)

(5-30 µg/mL)

(5-30 µg/mL)

Limit of quantification (µg/mL)

0.707

0.877

1.094

1.389

Limit of detection (μg/mL)

0.233

0.290

0.36

0.458

Robustness (RSD %)***

[chosen wavelength ± 2 nm]

1.737

0.689

0.779

1.103

  1. *The intra-day (n = 3), RSD of three concentration 20, 25, 30 µg/mL of MDF triplicate analysis within the day and
  2. **The inter-day (n = 3), RSD of three concentration 20, 25, 30 µg/mL of MDF triplicate analysis/day on three successive days by the suggested spectrophotometric methods
  3. ***RSD of MDF concentration of 15 µg/mL -repeatedly 3 times- were determined under minor wavelength variation [chosen wavelength for each method ± 2 nm]