Skip to main content

Table 1 The physico-chemical quality indicators measured before and after EC treatment process (electrolysis time = 30 min and pH = 7, max voltage = 15 V) from the three textile effluents

From: Investigation of selected physico-chemical quality parameters in industrial wastewater by electrocoagulation process, Ethiopia

Sites

Bahir Dar (BD)

Debre Brihan (DB)

Kombolcha (KO)

Water quality parameters

Before EC

After EC

RE (%)

Before EC

After EC

RE (%)

Before EC

After EC

RE (%)

Nitrate (mg/L)

9.24

1.50

84

0.85

0.06

93

2.00

0.97

52

Nitrite (mg/L)

0.624

0.038

94

0.030

0.002

93

0.178

0.08

55

Phosphate HR (mg/L)

1.8

0.9

50

18.0

9.4

48

14.0

6.4

54

Phosphate LR (mg/L)

0.06

0.03

50

3.76

2.00

47

1.25

0.04

97

Ammonia (mg/L)

8.00

1.00

88

20.00

2.60

87

0.63

0.02

61

Total nitrogen (TN) (mg/L)

17.86

2.54

86

20.88

2.66

87

2.81

1.07

62

PH

5.10

7.6

–

5.7

7.5

–

6.5

8

–

Conductivity(\(\mu\)s/cm)

557

113

79

1257

140

88.86

631

102

83.84

Temperature (ºC)

30.38

22.8

–

23.6

22.6

–

27.6

22.8

–

DO (mg/L)

3.74

4.52

–

3.39

4.83

–

4.49

4.81

 

Turbidity (NTU)

0.60

0.05

92

42.60

0.43

99

6.10

0.02

99

BOD (mg/L)

4.45

1.54

65

4.69

1.59

66

4.19

1.65

61

  1. Whereas RE removal efficiency, EC electrocoagulation