Skip to main content

Table 5 Comparison of the performance of prepared Zn-MOF-5@BHPAC nanocomposite-coated SPME fiber with other NSAIDs determination methods

From: Introduction of a Zn-based metal–organic framework @ biomass porous activated carbon as a high-sensitive coating for a stainless steel SPME fiber: application to the simultaneous analysis of nonsteroidal anti-inflammatory drugs

Analytical technique Samples LR (µg L−1) LOD (µg L−1) RSD% Extraction time (min) References
Electromembrane extraction-HPLC-UV Urine 0.68–8.40 0.20–0.27 2.71–10.20 10 [54]
DLLME-SFO-HPLC-UV Wastewater 1.00‒100 0.07‒0.19 3.05‒6.25 10 [55]
C18-SBSE-HPLC-UV Water 20.00‒2000 6.90‒7.69 4.10‒9.20 60 [56]
Zr‑MOF@GO-SPME-GC-FID Water 0.01–500 0.001–0.030 3.71‒3.77 40 [57]
Zn-MOF-5@BHPAC-SPME-HPLC-UV Water
Soil
0.20‒380 0.06‒0.15 1.40‒5.70 15 This work