Skip to main content

Table 5 Electrochemical parameters calculated from polarization measurements on copper and brass in 0.4 M NaCl + 0.1 M NaOH without and with 10−3 M of benzimidazole derivatives at 25 °C.

From: Recent advances in the use of benzimidazoles as corrosion inhibitors

 

Ecorr Ag/AgCl (V)

− βc (mV dec−1)

-βa (mV dec−1)

Icorr (μA cm−2)

IE (%)

Copper

 Blank

− 0.194

324

286

41.0

–

 44

− 0.153

206

196

3.67

91.0

 45

− 0.168

219

291

12.0

71.0

Brass

 Blank

− 0.437

483

136

118.0

–

 44

− 0.225

187

144

2.97

97.4

 45

− 0.200

232

116

9.1

92.0