Skip to main content

Table 1 Comparison with other reported methods for FB1 detection

From: A novel electrochemical aptasensor for fumonisin B1 determination using DNA and exonuclease-I as signal amplification strategy

Method

Amplification strategy

Linearity, (ng mL−1)

LOD, (ng mL−1)

Refs.

Chemiluminescence and enzyme-linked immunosorbent

ECL-ELISA based on anti-FB1 IgG and HRP

0.14–0.9

0.09

[17]

Chemiluminescence

Charge-coupled device

2.5–500

2.5

[18]

Fluorescence

Anti apt/Apt-NH2/TiO2-PSi

0.001–10

0.21 × 10−3

[5]

Fluorescence resonance energy transfer

AuNPs-MB-UCNPs

0.01–100

0.01

[19]

Electrochemiluminescence

MIP/Ru@SiO2/CS/AuNPs/GCE

1 × 10−3 ~ 100

0.35 × 10−3

[6]

Electrochemical immunosensor

AP-anti-antibody/anti-FB1/FB1-BSA-SWNTs/CS/GCE

0.01–1000

2 × 10−3

[20]

Electrochemical immunosensor

Ab-AuNPs-PPy/ErGO-SPE

200–4500

4.2

[21]

Electrochemical magneto immunosensor

FB1-HRP/Ab-FB1/MB&protein G/CSPE

0.73–11.2

0.33

[22]

Electrochemical aptasensor

Apt-AuNPs-SPCE

1 × 10−2~50

3.4 × 10−3

[7]

Electrochemical aptasensor

GS-TH/S2/S1/Au/GCE

1 × 10−3~1000

1 × 10−3

[23]

Electrochemical aptasensor

Exo-I/Apt/cDNA/AuE

1 × 10−3~1000

0.15 × 10−3

This work