Skip to main content

Table 6 Assay results for the determination of the studied analytes in spiked human urine, human plasma and breast milk using the proposed method

From: Rapid micellar HPLC analysis of loratadine and its major metabolite desloratadine in nano-concentration range using monolithic column and fluorometric detection: application to pharmaceuticals and biological fluids

Matrix

Parameters

LOR

DSL

Amount taken (ng/mL)

Amount found (ng/mL)

Relative recovery (%)a

Amount taken (ng/mL)

Amount found (ng/mL)

Relative recovery (%)a

Urine

Data

5.0

4.744

94.88

5.0

4.657

93.14

20.0

20.370

101.85

20.0

20.520

102.60

50.0

49.800

99.97

50.0

49.800

99.68

Mean

  

98.81

  

98.47

SD

  

3.57

  

4.84

% RSD

  

3.61

  

4.92

% error

  

2.08

  

2.84

Plasma

Data

5.0

4.687

93.74

5.0

4.584

91.68

20.0

20.477

102.39

20.0

20.631

103.16

50.0

49.900

99.71

50.0

49.800

99.61

Mean

  

98.61

  

98.15

SD

  

4.43

  

5.88

% RSD

  

4.49

  

5.99

% error

  

2.59

  

3.46

Breast milk

Data

5.0

4.700

94.0

5.0

4.624

92.48

20.0

20.457

102.29

20.0

20.566

102.83

50.0

49.900

99.72

50.0

49.800

99.63

Mean

  

98.67

  

98.31

SD

  

4.24

  

5.3

% RSD

  

4.3

  

5.39

% error

  

2.48

  

3.11

  1. aEach result is the average of three separate determinations