Skip to main content

Table 2 Analytical performance data for the determination of the studied analytes by the proposed method

From: Rapid micellar HPLC analysis of loratadine and its major metabolite desloratadine in nano-concentration range using monolithic column and fluorometric detection: application to pharmaceuticals and biological fluids

Parameter

LOR

DSL

Linearity range (ng/mL)

20.0–200.0

20.0–200.0

Intercept

−24.518

−18.97

Slope

1.844

1.749

Correlation coefficient (r)

0.9999

0.9999

SD of residuals (Sy/x)

1.140

0.856

SD of intercept (Sa)

0.9054

0.679

SD of slope (Sb)

8.314 × 10−3

6.243 × 10−3

% RSDa

1.08

1.17

MDL (ng/mL)b

15.0

13.0

LOQ (ng/mL)c

20.0

18.0

  1. aPercentage relative standard deviation
  2. bMethod detection limit
  3. cLimit of quantification