Skip to main content

Table 1 Comparison the performances of 4-nitrophenol detection based on doped Mn 2 O 3 -ZnO NPs using various reported methods

From: Chemo-sensors development based on low-dimensional codoped Mn2O3-ZnO nanoparticles using flat-silver electrodes

Materials

Methods

LDR

DL

Sensitivity

Linearity (r2)

Ref

CuO Nanohybrides

I-V

1.0 nM to 1.0 mM

0.67 nM.

4.50 μAcm-2 mM-1

0.7941

[93]

Poly(safranine) Film Electrode

CV/LSV

8.0 × 10−8 to 4.0 × 10−5 M

3.0 × 10−8 M

--

0.9880

[94]

Mn-Doped ZnS QDs

Chemilumine-scence (CL)

0.1 to 40 μM

76.0 nM

--

--

[95]

Immunoassay

Fluorescence Spectroscopy (FL)

5 and 1000 μg/L

3.5 nM

5.7 mg/L

--

[96]

Graphene Oxide sensors

CV

0.1 to 120 μM

0.02 μM

--

--

[97]

B-doped diomond Electrodes

SWV

--

8.4 mM

0.3943

0.9991

[98]

Doped Mn 2 O 3 -ZnO NPs/AgE

I-V method

0.1 nM to 50.0 μM

~4.6667 μAcm-2 μM-1

~0.83 nM

0.9773

Current work