Code Heightb Tbias RHbias Code Heightb Tbias RHbias
#1   −0.015 0.647 #14 0 0.405 −0.096
#2 185 −0.321 0.425 #15 30 0.175 −0.351
#3 290 −0.088 0.714 #16 0 0.027 −0.532
#4 153 −0.119 −0.365 #17 338 −0.298 −0.084
#5 0 0.018 0.760 #18 300 −0.438 0.495
#6 0 0.064 −0.208 #19 310 0.206 −1.506
#7 163 −0.168 0.372 #20 290 0.035 −0.198
#8 0 −0.204 0.342 #21 175 −0.424 0.464
#9 189 0.305 0.059 #22 240 0.291 −0.555
#10 240 −0.029 −0.550 #23 330 0.224 0.613
#11 0 0.199 0.204 #24 117 0.010 0.308
#12 210 −0.115 −1.112 #25 54 −0.304 0.233
#13 0 0.529 0.435 #26 15 0.036 −0.512
  1. aTemperature bias (Tbias in °C) and relative humidity bias (RHbias in %), averaged for both calibration periods (codes as in Figure 17).
  2. bDistance to the floor level (cm).