Skip to main content

Table 1 Analytical parameters for the analysis of the studied drugs by the proposed spectrophotometric method

From: Spectrophotometric determination of tizanidine and orphenadrine via ion pair complex formation using eosin Y

Parameter (a)

Tizanidine(I)

Orphenadrine(II)

Wavelength(nm)

545

542

Concentration range(μg/mL)

0.5-8

1-12

Limit of detection (LoD) (μg/mL)

0.1

0.3

Limit of quantification(LoQ) (μg/mL)

0.26

0.95

Correlation coefficient

0.9999

0.9998

Slope

0.12

0.09

Intercept

0.11

0.032

S y/x

5.43 × 10-3

0.013

S a

3.2 × 10-3

8.84 × 10-3

S b

7.06 × 10-4

1.29 × 10-3

RSD,%

1.20

1.60

% Error

0.45

0.64

ε (l/mol./cm.)

4.26 × 104

4.63 × 104

  1. (a) Sy/x: standard deviation of the residuals; Sb: standard deviation of the slope,
  2. %Error = % RSD/√n; Sa, standard deviation of the intercept; and ε, molar absorptivity.